Background: High-dose radiotherapy of lung cancer is challenging. Tumors may move by up to 2 cm in craniocaudal and anteroposterior directions as a function of breathing cycle. Tumor displacement increases with treatment time, which consequentially increases the treatment uncertainty.

Objective: This study analyzed whether automatically gated cone-beam-CT (CBCT)-controlled intensity modulated fast deep inspiration breath hold (DIBH) stereotactic body radiation therapy (SBRT) in flattening filter free (FFF) technique and normofractionated lung DIBH intensity-modulated radiotherapy (IMRT)/volumetric-modulated arc therapy (VMAT) treatments delivered with a flattening filter can be applied with sufficient accuracy within a clinically acceptable timeslot.

Materials And Methods: Plans of 34 patients with lung tumors were analyzed. Of these patients, 17 received computer-controlled fast DIBH SBRT with a dose of 60 Gy (5 fractions of 12 Gy or 12 fractions of 5 Gy) in an FFF VMAT technique (FFF-SBRT) every other day and 17 received conventional VMAT with a flattening filter (conv-VMAT) and 2-Gy daily fractional doses (cumulative dose 50-70 Gy).

Results: FFF-SBRT plans required more monitor units (MU) than conv-VMAT plans (2956.6 ± 885.3 MU for 12 Gy/fraction and 1148.7 ± 289.2 MU for 5 Gy/fraction vs. 608.4 ± 157.5 MU for 2 Gy/fraction). Total treatment and net beam-on times were shorter for FFF-SBRT plans than conv-VMAT plans (268.0 ± 74.4 s vs. 330.2 ± 93.6 s and 85.8 ± 25.3 s vs. 117.2 ± 29.6 s, respectively). Total slot time was 13.0 min for FFF-SBRT and 14.0 min for conv-VMAT. All modalities could be delivered accurately despite multiple beam-on/-off cycles and were robust against multiple interruptions.

Conclusion: Automatically gated CBCT-controlled fast DIBH SBRT in VMAT FFF technique and normofractionated lung DIBH VMAT can be applied with a low number of breath-holds in a short timeslot, with excellent dosimetric accuracy. In clinical routine, these approaches combine optimally reduced lung tissue irradiation with maximal delivery precision for patients with small and larger lung tumors.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00066-015-0934-zDOI Listing

Publication Analysis

Top Keywords

automatically gated
12
flattening filter
12
lung cancer
8
increases treatment
8
fff technique
8
technique normofractionated
8
normofractionated lung
8
lung dibh
8
lung tumors
8
fast dibh
8

Similar Publications

This paper examines the design of antennas for Hi-pass type turnstiles needed to implement a subway free-pass system targeting transportation-disadvantaged individuals. The subway free-pass system allows individuals who have a free-pass card to approach the turnstile with the card on their person, which opens the gate automatically. This system, like the highway Hi-pass, allows users to pass through the subway gate without needing to scan a ticket.

View Article and Find Full Text PDF

In the rapidly developing field of wireless communications, the precise classification of modulated signals is essential for optimizing spectrum utilization and improving communication quality. However, existing networks face challenges in robustness against signals containing phase shift keying and computational efficiency. This paper introduces TCN-GRU, a lightweight model that combines the advantages of multiscale feature extraction of the temporal convolutional network (TCN) and global sequence modeling of gated recurrent unit (GRU).

View Article and Find Full Text PDF

In the human heart, the binding of cyclic adenosine monophosphate (cAMP), a second messenger, to hyperpolarization and cyclic nucleotide-gated (HCN) regulates the automaticity of pacemaker cells. Recent single-molecule binding studies show that cAMP bound to each subunit of purified tetrameric HCN channels independently, in contrast to findings in cells. To explore the lipid membrane's role in cAMP regulation, we reconstituted purified human HCN channels in various lipid nanodiscs and resolved single molecule ligand-binding dynamics.

View Article and Find Full Text PDF
Article Synopsis
  • HCN ion channels play a key role in cellular activity and pain perception, with propofol acting as an analgesic by inhibiting their function.
  • Researchers used a propofol analog to pinpoint binding sites on the human HCN1 isoform, revealing a specific pocket formed by certain residues in the channel.
  • Mutations in this binding pocket affect propofol's ability to modulate HCN1 currents, highlighting its specific binding mechanism and offering insights for developing targeted HCN channel modulators.
View Article and Find Full Text PDF

Early diagnosis of neurodegenerative diseases, such as Alzheimer's disease, improves treatment and care outcomes for patients. Early signs of cognitive decline can be detected using functional scales, which are written records completed by a clinician or carer, detailing a patient's capability to perform routine activities of daily living. For example, tasks requiring planning, such as meal preparation, are some of the earliest affected by early mild cognitive impairment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!