Background: Left ventricular outflow tract obstruction (LVOT) is an independent predictor of adverse outcome in hypertrophic cardiomyopathy (HCM). It is of major importance that the provocation modalities used are validated against each other.
Aim: To define the magnitude of LVOT gradients provocation during both isosorbide dinitrate (ISDN) inhalation and treadmill exercise in non-obstructive HCM and analyze the correlation to the electromechanical delay using speckle tracking.
Methods: We studied 39 HCM pts (64% males, mean age 38 ± 13 years) regional LV longitudinal strain and electromechanical delay (TTP) was analyzed at rest using speckle tracking. LVOT gradient was measured at rest and after ISDN then patients underwent a treadmill exercise echocardiography (EE) and LVOT gradient was measured at peak exercise.
Results: The maximum effect of ISDN on LVOT gradient was obtained at 5 minutes, it increased to a significant level in 12 (31%) patients, and in 14 (36%) patients using EE, with 85.6% sensitivity & 100% specificity. Patients with latent obstruction had larger left atrial volume and lower E/A ratio compared to the non-obstructive group (p < 0.01). LVOTG using ISDN was significantly correlated with that using EE (p < 0.0001), resting LVOTG (p < 0.0001), SAM (p < 0.0001), EF% (p < 0.02) and regional electromechanical delay but not related to global LV longitudinal strain. Using multivariate regression, resting LVOTG (p = 0.006) & TTP mid septum (p = 0.01) were found to be independent predictors of latent LVOT obstruction using ISDN.
Conclusion: There is a comparable diagnostic value of nitrate inhalation to exercise testing in provocation of LVOT obstruction in HCM. Latent obstruction is predominantly dependent on regional electromechanical delay.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4448073 | PMC |
http://dx.doi.org/10.5339/gcsp.2015.15 | DOI Listing |
J Neurophysiol
January 2025
Department of Integrative Physiology, University of Colorado Boulder.
Our purpose was to compare the influence of the spectral content of motor unit recordings on the calculation of electromechanical delay and on the prediction of force fluctuations from measures of the variability in discharge times and neural drive during steady isometric contractions with the first dorsal interosseus muscle. Participants ( = 42; 60 ± 13 yrs) performed contractions at 5% and 20% MVC. After satisfying inclusion criteria, high-density surface EMG recordings from a subset of 23 participants were decomposed into the discharge times of 530 motor units.
View Article and Find Full Text PDFMicrosyst Nanoeng
January 2025
Key Laboratory of Instrumentation Science and Dynamic Measurement Ministry of Education, North University of China, 030051, Taiyuan, China.
The alarming prevalence and mortality rates associated with cardiovascular diseases have emphasized the urgency for innovative detection solutions. Traditional methods, often costly, bulky, and prone to subjectivity, fall short of meeting the need for daily monitoring. Digital and portable wearable monitoring devices have emerged as a promising research frontier.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Robotics and Mechatronics, Tokyo Denki University, Tokyo 120-8551, Japan.
As robots become increasingly integrated into human society, the importance of human-machine interfaces continues to grow. This study proposes a faster and more accurate control system for myoelectric prostheses by considering the Electromechanical Delay (EMD), a key characteristic of Electromyography (EMG) signals. Previous studies have focused on systems designed for wrist movements without attempting implementation.
View Article and Find Full Text PDFEgypt Heart J
January 2025
Department of Cardiology, Hangzhou First People's Hospital, #261 Huansha Road, Hangzhou, 310000, Zhejiang Province, China.
Background: To investigate the optimization of leadless pacemaker placement and to assess its impact on heart synchronization and tricuspid regurgitation.
Results: A clinical trial was conducted involving 53 patients who underwent leadless pacemaker implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine and Hangzhou First People's Hospital between March 2022 and February 2023. Implantation site localization was determined using the 18-segment method under RAO 30° imaging.
Ann Med Surg (Lond)
December 2024
Wayne State University, Detroit, MI, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!