Background: An outbreak of eye diseases occurred among workers at a poultry abattoir in South Korea from December 2012 to June 2013. An epidemiological investigation of the causative agent was conducted. The workers were given a special health examination and workplace environmental monitoring was performed. Workers with ocular symptoms subsequently underwent an ophthalmic examination.
Case Presentaion: From a total of 41 workers, 26 (63.4 %) were diagnosed with keratoepitheliopathy by ophthalmic examination. Environmental monitoring of the workplace revealed that the ultraviolet (UV) apron-disinfection lamp had not been turning off at the set times, and so the workers' faces had been exposed to UV radiation. Effective radiation dose measurement showed a UV-B exposure of 7-30 μW/cm(2), and a UV-C exposure of 40-200 μW/cm(2); both values exceed the occupational exposure limits. The outbreak ceased after the lamp was repaired.
Conclusions: This case shows that inappropriate use of the UV disinfection lamp can cause mass photokeratitis. In order to prevent this, the UV disinfection lamp must be checked regularly, workers must be educated on the health effects of UV radiation, and appropriate eye protection must be worn.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4714468 | PMC |
http://dx.doi.org/10.1186/s40557-015-0087-7 | DOI Listing |
Sci Rep
December 2024
Department of Microbiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Respiratory interventions including noninvasive ventilation, continuous positive airway pressure and high-flow nasal oxygen generated infectious aerosols may increase risk of airborne disease (SARS-CoV-2, influenza virus) transmission to healthcare workers. We developed and tested a prototype portable UV-C device to sterilize high flows of viral-contaminated air from a simulated patient source at airflow rates of up to 100 l/m. Our device consisted of a central quartz tube surrounded 6 high-output UV-C lamps, within a larger cylinder allowing recirculation past the UV-C lamps a second time before exiting the device.
View Article and Find Full Text PDFInfect Control Hosp Epidemiol
December 2024
Infection Control and Prevention Unit, Shaare Zedek Medical Center, Jerusalem, Israel.
Objective: To upgrade cleaning and disinfection of patient rooms in a crowded emergency department (ED).
Setting: Tertiary referral hospital.
Design: Prospective, 3-component, before-and-after intervention study.
Photochem Photobiol
December 2024
Department of Ophthalmology, Shimane University Faculty of Medicine, Izumo, Japan.
The ocular safety of 222-nm far-ultraviolet-C (UV-C) irradiation, widely recognized for its germicidal properties, was evaluated in a clinical setting to assess its long-term health effects on the human eye. This prospective observational study involved a 36-month follow-up of physicians working in an ophthalmic examination room equipped with 222-nm UV-C lamps. Initially, a 12-month observation showed no signs of acute or chronic ocular damage.
View Article and Find Full Text PDFJ Hazard Mater
November 2024
School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong; Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong. Electronic address:
Ultraviolet germicidal irradiation (UVGI) technology can inhibit the environmental transmission of airborne pathogens, but the dose-response behavior of airborne human coronavirus and wavelength-specific inactivation mechanisms are not well understood. This study investigated three competitive UVC sources for their inactivation efficacy and mechanisms against human coronavirus OC43 (HCoV-OC43). Results showed the following order of inactivation efficacy: 222-nm KrCl excimer lamp > 263-nm UV-LEDs > 254-nm low-pressure mercury lamp.
View Article and Find Full Text PDFCureus
October 2024
Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, USA.
Background: The relative importance of different ultraviolet-C (UV-C) emitter configurations on the attenuation of vegetative bacterial and fungal pathogens has not been assessed. We hypothesized that emitter configuration would impact the efficacy of UV-C attenuation of and ( pathogens.
Methods: American Type Culture Collection (ATCC) (ATCC 6538) and (ATCC MYA-5001 carriers (ReadyNowTM Test Carriers, Stratix Labs Corporation, Saint Paul, MN) were mounted on an aluminum stand along with three calibrated radiometers (International Light Technologies model ILT1270, Peabody, MA).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!