Background/aim: We aimed to define the optimal SUV(max) cut-off value in determination of mediastinal-hilar lymph node metastasis, by comparing positive PET/CT results with the results of endobronchial ultrasound guided transbronchial needle aspiration biopsy (EBUS-TBNA).

Materials And Methods: Thirty-one patients with malignancy whose PET/CT imaging revealed a hypermetabolic mediastinal and/or hilar lymph node and who had undergone EBUS-TBNA were evaluated retrospectively. Histopathology was regarded as the gold standard. The diagnostic role of PET/CT in mediastinal/hilar lymph node metastasis was investigated and compared with the results of contrast-enhanced CT.

Results: When a SUV(max) value of 2.5 was used, the sensitivity, positive predictive value (PPV), and diagnostic accuracy of the PET/CT were 100%, 65.4%, and 65.4% respectively. In the ROC analysis, the SUV(max) cut-off value with the highest diagnostic accuracy (75%) was calculated as 6.3, and when this value was considered, the sensitivity, specificity, PPV, negative predictive value, and diagnostic accuracy of the PET/CT were determined as 70.6%, 83.3%, 88.9%, 60%, and 75% respectively (AUC: 0.779). The sensitivity, PPV, and diagnostic accuracy of the thorax CT were calculated as 91.1%, 72%, and 71.1%, respectively.

Conclusion: When determining mediastinal-hilar lymph node metastasis via PET/CT, although a SUV(max) cut-off value of 6.3 increases specificity and diagnostic accuracy, we think that a SUV(max) cut-off value of 2.5 and above give more optimal results in routine practice.

Download full-text PDF

Source

Publication Analysis

Top Keywords

diagnostic accuracy
20
suvmax cut-off
16
lymph node
16
mediastinal-hilar lymph
12
node metastasis
12
ppv diagnostic
8
accuracy pet/ct
8
pet/ct
7
diagnostic
6
lymph
5

Similar Publications

Early cancer detection substantially improves the rate of patient survival; however, conventional screening methods are directed at single anatomical sites and focus primarily on a limited number of cancers, such as gastric, colorectal, lung, breast, and cervical cancer. Additionally, several cancers are inadequately screened, hindering early detection of 45.5% cases.

View Article and Find Full Text PDF

Aim: Ultrasonography (US) has shown accuracy in imaging healthy periodontium. This study aims to evaluate the feasibility and accuracy of US for estimating dimensions of inflamed periodontium induced by ligature and bacteria.

Methods: Periodontal tissues of maxillary as well as mandibular premolars and molars in six female mini pigs were treated with ligature and three strains of bacteria for 4-10 weeks.

View Article and Find Full Text PDF

This study investigates the prognostic value of serum biomarkers PD-L1 and IGFBP-2 in patients with esophageal carcinoma. It finds a significant positive correlation between these biomarkers and established tumor markers CEA and CYFRA21-1. The 3-year survival rate for the patient cohort was 45.

View Article and Find Full Text PDF

Purpose: The study aimed to develop a deep learning model for rapid, automated measurement of full-spine X-rays in adolescents with Adolescent Idiopathic Scoliosis (AIS). A significant challenge in this field is the time-consuming nature of manual measurements and the inter-individual variability in these measurements. To address these challenges, we utilized RTMpose deep learning technology to automate the process.

View Article and Find Full Text PDF

Enhancing newborn screening sensitivity and specificity for missed NICCD using selected amino acids and acylcarnitines.

Orphanet J Rare Dis

January 2025

Department of Genetics and Metabolism, Children's Hospital of Zhejiang University School of Medicine, National Clinical Research Center for Child Health, No. 3333 Binsheng Road, Binjiang District, Hangzhou, 310053, Zhejiang, China.

Purpose: To enhance the detection rate of Neonatal Intrahepatic Cholestasis caused by Citrin Deficiency (NICCD) through newborn screening (NBS), we analyzed the metabolic profiles of missed patients and proposed a more reliable method for early diagnosis.

Methods: In this retrospective study, NICCD patients were classified into "Newborn Screening" (64 individuals) and "Missed Screening" (52 individuals) groups. Metabolic profiles were analyzed using the non-derivatized MS/MS Kit, and genetic mutations were identified via next-generation sequencing and confirmed by Sanger sequencing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!