A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of different post space irrigation procedures on the bond strength of a fiber post attached with a self-adhesive resin cement. | LitMetric

Statement Of Problem: The effects of different post space irrigation procedures on the bond strength of a self-adhesive resin cement to the root canal dentin are still unclear.

Purpose: The purpose of this in vitro study was to evaluate the effects of alternative post space irrigation procedures on the cement strengths of posts attached with a self-adhesive resin cement.

Material And Methods: Forty single-rooted teeth were selected, and after root canal preparation and obturation, post spaces were prepared. The teeth were divided into 4 groups corresponding to the post space irrigation procedure and treated as follows: the distilled water (DW) group (control) received 15 mL of distilled water; the NaOCl+ethylenediaminetetraacetic acid (EDTA) group was treated with 5 mL of 5.25% NaOCl, 5 mL of 17% EDTA, and 5 mL of distilled water; the chlorhexidine (CHX) group was treated with 15 mL of 2% chlorhexidine solution; and the phosphoric acid (PA) group treatment consisted of etching the walls of the prepared post holes with 35% phosphoric acid. Fiber posts were attached with a self-adhesive resin cement, and specimens were cut horizontally for push-out testing. The statistical evaluation consisted of 1-way ANOVA with the post hoc Tukey honest significant differences test (α=.05).

Results: The NaOCl+EDTA treatment yielded a significantly higher bond strength than those used in the other 3 groups (P=.003). No statistically significant differences were found among any of the other groups, as different root regions showed similar bond strength values (P>.05).

Conclusions: The results showed that EDTA in combination with NaOCl could be advantageous for post space irrigation when fiber posts are bonded with a self-adhesive resin cement.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2015.10.010DOI Listing

Publication Analysis

Top Keywords

post space
20
space irrigation
20
self-adhesive resin
20
bond strength
16
resin cement
16
irrigation procedures
12
attached self-adhesive
12
distilled water
12
post
9
procedures bond
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!