Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Pulmonary hypertension (PH) is a common problem in the neonatal intensive care unit and is associated with significant morbidity and mortality. The aim of this study was to identify a quantitative echocardiographic marker of septal curvature that can be used to accurately identify PH in NICU infants with concern for PH.
Methods: Echocardiograms of infants who were prematurely born and infants with persistent pulmonary hypertension of the newborn were performed using a defined protocol for evaluation of PH. Qualitative assessment by a single pediatric cardiologist was used as a reference standard. Qualitative and quantitative parameters of right ventricular (RV) size, pressure, and function were documented. Left ventricular end-systolic eccentricity index (EI) was defined as the ratio of the anterior-inferior and septal-posterolateral cavity dimensions at the mid-ventricular level.
Results: A total of 216 infants at risk for PH were included in this study. One hundred forty-three (66%) had an interpretable tricuspid regurgitation jet velocity. While systolic septal flattening was recognized at EIs ≥ 1.15, more than half-systemic RV pressure became apparent at EIs ≥ 1.3. Unlike qualitative assessment of septal flattening, there was high inter-observer agreement for EIs. Quantitative parameters of RV systolic function were impaired only at EIs ≥ 1.3.
Conclusions: We suggest that EIs should be incorporated into routine protocols when there is a concern for PH in neonates. This may lead to a more reliable assessment of PH and may reduce inter-observer variability. Correlation of EIs with invasive hemodynamic data is needed to validate our results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/echo.13171 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!