Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To assess the diagnostic accuracy of ultrasonographic optic nerve sheath diameter (ONSD) measurement and color Doppler indices of the ophthalmic arteries in detecting elevated intracranial pressure (ICP).
Patients And Methods: A total 60 patients with (cases, n=30) and without (controls, n=30) acute clinical and computed tomographic findings of elevated ICP due to intracranial mass/hemorrhage were recruited from a teaching hospital. The mean binocular and maximum ultrasonographic ONSDs, as well as the mean binocular Doppler ultrasound waveform indices of the ophthalmic arteries including pulsatility index (PI), resistive index (RI), end-systolic velocity (ESV), peak systolic velocity (PSV) and end-diastolic velocity (EDV) were compared between the two groups.
Results: Compared to controls, the case group had significantly higher mean binocular ONSD (5.48 ± 0.52 mm vs. 4.09 ± 0.22 mm, p<0.001), maximum ONSD (5.63 ± 0.55 mm vs. 4.16 ± 0.23 mm, p<0.001), mean PI (1.53 ± 0.16 vs. 1.45 ± 0.20, p=0.01), and mean RI (0.76 ± 0.07 vs. 0.73 ± 0.04, p=0.01). The mean EDV, in contrast, was significantly higher in controls (8.55 ± 3.09 m/s vs. 7.17 ± 2.61 m/s, p=0.01). The two groups were comparable for the mean PSV (30.73 ± 7.93 m/s in cases vs. 32.27 ± 10.39 m/s in controls, p=0.36). Among the mentioned variables, the mean binocular ONSD was the most accurate parameter in detecting elevated ICP (sensitivity and specificity of 100%, cut-off point=4.53 mm). The Doppler indices were only moderately accurate (sensitivity: 56.7-60%, specificity: 63.3-76.7%).
Conclusion: While the ultrasonographic mean binocular ONSD (>4.53 mm) was completely accurate in detecting elevated ICP, color Doppler indices of the ophthalmic arteries were of limited value.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clineuro.2015.12.007 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!