The purpose of this study is to obtain normative values of the masseter muscle of myasthenia gravis (MG) patients and healthy volunteers by single-fiber electromyography (SFEMG). Stimulation of SFEMG in the masseter muscle was studied in 15 healthy volunteers (men 8, women 7; mean age 40.2, range 21-77) and 30 patients affected by MG (men 16, women 14; mean age 42.8, range 12-75). The mean consecutive difference (MCD) of the individual fiber and the mean MCD per study were determined in the normal group. We recommend the upper normal limit for the individual fibers of jitter and the mean MCD per study in the healthy Chinese adults of 33 µs and 22 µs respectively. Furthermore, in the MG group, the percentage of jitter > upper normal limit jitter and the impulse blocking percentage were detected, which were all significantly different compared to the normal control group (P < 0.01). The overall sensitivity was 90%, with the abnormality in 6 of the 9 ocular MG patients and 100% abnormality in the generalized MG patients. The masseter muscle SFEMG has a high degree of sensitivity. The masseter should be considered for SFEMG in the diagnosis of MG, and added routinely to the tested muscles.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4694486PMC

Publication Analysis

Top Keywords

masseter muscle
16
normative values
8
values masseter
8
single-fiber electromyography
8
myasthenia gravis
8
gravis patients
8
healthy volunteers
8
men women
8
women age
8
mcd study
8

Similar Publications

Importance: Biomarkers would greatly assist decision-making in the diagnosis, prevention, and treatment of chronic pain.

Objective: To undertake analytical validation of a sensorimotor cortical biomarker signature for pain consisting of 2 measures: sensorimotor peak alpha frequency (PAF) and corticomotor excitability (CME).

Design, Setting, And Participants: This cohort study at a single center (Neuroscience Research Australia) recruited participants from November 2020 to October 2022 through notices placed online and at universities across Australia.

View Article and Find Full Text PDF

The aim of this study was to compare the effectiveness of different types of low level laser treatment (LLLT) in reducing pain levels, changing oxygen saturation and bite force in patients with myofacial pain syndrome (MPS). 45 patients were randomly assigned to three groups: Group 1 (GRR laser, n = 15) received LLLT with Gallium-Aluminium-Arsenide (GaAlAs) diode laser with a wavelength of 904 nm and red laser with a wavelength of 650 nm over masseter muscle region. Group 2 (Nd: YAG laser, n = 15) were treated with Neodymium-doped Yttrium Aluminium Garnet laser with a wavelength of 1064 nm and the same protocol with Nd: YAG laser was performed in the Group 3 (placebo, n = 15) using sham device.

View Article and Find Full Text PDF

Background: Botulinum toxin is an attenuated neurotoxin of Clostridium Botulinum gram positive bacterial, which is used in medication sialorrhea, cervical dystonia, hyperhidrosis and non-surgical cosmetic operation (aesthetic) such as facial wrinkles and reduced the bulky appearance hypertrophied of masseter muscle. This study was designed to revealed the effect of zygomiticus inoculation of botulinum toxin B in zygomatic muscle of rats on zygomatic bone.

Methods: A total of 25 male albino rats (200-260 gm) were injected facial intramuscular by a single dose of 2.

View Article and Find Full Text PDF

Hardness is one of the dominant sensory characteristics of food. This study estimated the effect of sensitivity to hardness on the texture perception and chewing function using 2, 4, and 6% agar gels. Increasing the concentration of agar resulted in an increase in gel hardness and springiness, measured by texture profile analysis.

View Article and Find Full Text PDF

Background: Awake bruxism involves masticatory muscle activity during wakefulness, potentially leading to clinical concerns. Accurate electromyography (EMG) assessment is challenging with brief durations.

Objective: To establish a reliable, short-term measure for nonfunctional masseter muscle activity during wakefulness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!