Since 2009, the peritoneal dialysis (PD) registry survey has been carried out as part of the annual nationwide survey conducted by the Statistical Survey Committee of the Japanese Society for Dialysis Therapy with the cooperation of the Japanese Society for Peritoneal Dialysis. In this report, the current status of PD patients is presented on the basis of the results of the survey conducted at the end of 2012. The subjects were PD patients who lived in Japan and participated in the 2012 survey. Descriptive analysis of various items was performed, which included the current status of the combined use of PD and another dialysis method such as hemodialysis (HD) or hemodiafiltration (HDF), the method of exchanging dialysate, the use of an automated peritoneal dialysis (APD) machine, and the rates of peritonitis and catheter exit-site infection. From the results of the facility survey in 2012, the number of PD patients was 9514, a decrease of 128 from 2011. Among the entire dialysis patient population, 3.1% were PD patients, a decrease of 0.1%. Among the studied patients, 347 had a peritoneal catheter and underwent peritoneal lavage, 175 were started on PD in 2012 but introduced to other blood purification methods in the same year, and 1932 underwent both PD and another dialysis method such as HD or HDF. The percentage of patients who underwent PD and another dialysis method increased with PD vintage: <1 year, 4.8%; 1 to <2 years, 9.2%; 2 to <4 years, 16.3%; 4 to <8 years, 32.0%; and ≥8 years, 47.5%. The percentage of PD patients who completely manually exchanged the dialysate was 29.8%. The percentages of PD patients who used a double-bag exchange system with ultraviolet-light irradiation and those who used the same system but with a sterile connecting device were 54.7 and 13.9%, respectively. The percentage of patients on PD for <1 year using an APD machine was 43.4%, and it decreased with a PD vintage of ≥2 years. The mean rate of peritonitis was 0.22 per patient per year. The mean rate of catheter exit-site infections was 0.36 per patient per year.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1744-9987.12382DOI Listing

Publication Analysis

Top Keywords

peritoneal dialysis
16
dialysis method
12
dialysis registry
8
2012 survey
8
dialysis
8
survey conducted
8
japanese society
8
current status
8
underwent dialysis
8
survey
7

Similar Publications

The gut microbiota alterations interact with the pathogenesis and progression of chronic kidney disease (CKD). Probiotics have received wide attention as a potential management in CKD. We investigated the effects of Lactobacillus paracasei N1115 (LP N1115) on intestinal microbiota and related short-chain fatty acids (SCFAs) in end stage kidney disease patients on peritoneal dialysis (PD) in a single-center, prospective, randomized, double-blind, placebo-controlled study.

View Article and Find Full Text PDF

The electricity cost burden of durable medical equipment in the United States.

Sci Rep

December 2024

Paul H. O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, USA.

Those who rely on durable medical equipment (DME) for their health are more likely to be energy insecure and face higher energy burdens than those who do not. In this article, we evaluate the costs of electricity to run DMEs. We find that the average cost across the most common types of high-frequency DMEs-including oxygen concentrators, continuous positive airway pressure machines, and peritoneal kidney dialysis machines-is between $120 and $333 per year, depending on device size and usage frequency.

View Article and Find Full Text PDF

Purpose: With the increasing demand for dialysis, there is a growing emphasis on patient-centered care. This study investigated patients' satisfaction levels with peritoneal dialysis (PD) and hemodialysis (HD) care in Iran.

Methods: A cross-sectional multicenter study was conducted among 346 patients with chronic kidney disease (CKD) covered by the Iran Health Insurance Organization who received dialysis services from October to December 2022 across the country.

View Article and Find Full Text PDF

Trimethylamine -oxide (TMAO), a gut microbiome-derived metabolite, participates in the atherogenesis and vascular stiffening that is closely linked with cardiovascular (CV) complications and related deaths in individuals with kidney failure undergoing peritoneal dialysis (PD) therapy. In these patients, arterial stiffness (AS) is also an indicator of adverse CV outcomes. This study assessed the correlation between serum TMAO concentration quantified with high-performance liquid chromatography and mass spectrometry and central AS measured by carotid-femoral pulse wave velocity (cfPWV) in patients with chronic PD.

View Article and Find Full Text PDF

Peritoneal dialysis (PD) serves as a home-based kidney replacement therapy with increasing utilization across the globe. However, long-term use of high-glucose-based PD solution incites repeated peritoneal injury and inevitable peritoneal fibrosis, thus compromising treatment efficacy and resulting in ultrafiltration failure eventually. In the present study, we utilized human mesothelial MeT-5A cells for the in vitro experiments and a PD mouse model for in vivo validation to study the pathophysiological mechanisms underneath PD-associated peritoneal fibrosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!