Background: For the fixation of displaced midshaft clavicular fractures different plates are available, each with its specific pros and cons. The ideal plating choice for this lesion remains subject to ongoing discussion. Reconstruction plates are cheap and easily bendable, but their strength and stability have been questioned. The aim of this study was to evaluate the failure rate of reconstruction plates in the fixation of clavicular fractures.

Materials And Methods: A multicenter, retrospective cohort study of all consecutive patients with a displaced, midshaft clavicular fracture (Robinson type 2a/2b) treated with a 3.5-mm reconstruction plate between 2006 and 2013 were evaluated. The primary outcome measure was reoperation rate due to implant failure. Secondary outcome measures were nonunion, symptomatic malunion and elective plate removal.

Results: One hundred and eleven patients were analyzed. During a median follow-up of 8 months, 14 patients (12.6%) had implant failure, of which 7 (6.3%) required a reoperation. Three nonunions (2.7%) and no symptomatic malunions occurred. Plate removal was indicated in 37.8% of patients because of implant irritation.

Discussion: The incidence of reoperation due to implant failure following clavicular plate fixation with a reconstruction plate is 6.3%. Although comparison with other plate types is difficult since rates in literature vary greatly, reoperation rates in other plates are reported around 2-3%, suggesting that reconstruction plates have a higher incidence of implant failure warranting reoperation. Therefore, especially in patients with known risk factors for complications (e.g. smoking, osteoporosis, comminuted fractures), a stronger plate than a reconstruction plate should be considered.

Level Of Evidence: Level IV. Retrospective study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2015.11.008DOI Listing

Publication Analysis

Top Keywords

reconstruction plates
16
implant failure
16
midshaft clavicular
12
reconstruction plate
12
clavicular fractures
8
retrospective cohort
8
cohort study
8
displaced midshaft
8
plate
8
reconstruction
7

Similar Publications

Clinical characteristics and removal of broken burs retained in the lower jaw.

BMC Oral Health

January 2025

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.

Background: A broken bur retained in the lower jaw is an uncommon complication that occurs during the extraction of the impacted mandibular third molar. The purpose of this retrospective study was to investigate the clinical characteristics of the broken burs and review our experience with the removal of the broken burs in these cases.

Methods: All patients, who suffered the broken bur remained in the lower jaw due to the extraction of the impacted mandibular third molar and presented to our hospital from July 2019 to July 2024, were included in this retrospective study.

View Article and Find Full Text PDF

Objective: This study presents a novel digital interproximal enamel reduction (IER) clinical procedure, aiming to improve the effectiveness of IER processes in orthodontic treatment.

Methods: A malocclusion case of skeletal-class I and angle-class I was selected for the experimental investigation. A three-dimensional (3D) model of the dentition was constructed using scanning data from a plaster model.

View Article and Find Full Text PDF

Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.

View Article and Find Full Text PDF

This study aims to evaluate and compare the usability and performance of mixed reality (MR) technology versus conventional methods for preoperative planning of patient-specific reconstruction plates for orbital fractures. A crossover study design was used to compare MR technology with conventional three-dimensional (3D) printing approaches in the planning of maxillofacial traumatology treatments. The primary focus was on user-friendliness and the accuracy of patient-specific reconstruction planning.

View Article and Find Full Text PDF

Unlabelled: A new lower tooth plate of from the Turonian (Upper Cretaceous) of the Dalmatian region (southern Croatia) is documented here for the first time. The specimen represents the first articulated dentition of a ptychodontid shark that has been discovered from the Balkan Peninsula and the most complete ever found for the un-cuspidate species up to now. The reconstruction of the entire lower dentition of based on this exceptionally well-preserved dentition shows a wider crushing plate than previously hypothesised with bulgy teeth limited to the central area.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!