Influence of the indirect restoration design on the fracture resistance: a finite element study.

Biomed Eng Online

Faculty of Dentistry, The University of Hong Kong, 34 Hospital Road, Hong Kong SAR, China.

Published: January 2016

AI Article Synopsis

  • A 3D finite element model was created to analyze the stress on a maxillary first premolar and its dental restorations when subjected to various occlusal forces.
  • The study involved digitally scanning a tooth and designing different sizes of indirect composite resin inlays and onlays, which were then tested for stress response under vertical and oblique forces.
  • Results showed that larger inlays experienced significantly higher stress under oblique loads compared to adjacent dentine, indicating that larger composite restorations can effectively reduce stress on the tooth structure when properly designed.

Article Abstract

Objectives: To establish a three-dimensional (3D) finite element (FE) model of a maxillary first premolar and to evaluate the stress generated on the tooth (dentine) and on the indirect composite resin restorations by occlusal forces.

Methods: An embedded intact maxillary first premolar tooth was sliced serially and scanned digitally parallel to the occlusal surface. The 64 images were assembled in a 3D FE mesh and exported to generate a 3D solid tooth model. Simulated, adhesively cemented indirect mesial-occlusal-distal (MOD) inlays of 2 mm (I1), 3 mm (I2) and 4 mm (I3) in width, and MOD onlays with occlusal cusp coverage of 2 mm (O1) and 3 mm (O2) in depth were created. The peak von Mises stress values in the five tooth models resulting from static vertical and oblique occlusal forces (300 N) were evaluated using Patran FE software.

Results: The peak stress values generated by vertical occlusal force generated in dentine of I1, I2, I3, O1 and O2 restoration were 67, 32, 29, 38 and 27 MPa, respectively, and those generated by oblique occlusal force were 52, 114, 168, 54 and 55 MPa, respectively. The peak von Mises stress values in I1, I2, I3, O1 and O2 restoration subjected to oblique occlusal loading were 79, 120, 1740, 1400 and 1170 MPa, respectively.

Conclusion: A 3D FE model of a maxillary first premolar was established. Simulated cemented composite resin onlay markedly reduces occlusal stress in the underlying dentine of large MOD preparation. Oblique occlusal force imparts substantially higher stress to large composite resin inlay than to the adjacent dentine.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5002181PMC
http://dx.doi.org/10.1186/s12938-015-0115-4DOI Listing

Publication Analysis

Top Keywords

oblique occlusal
16
maxillary premolar
12
composite resin
12
stress values
12
occlusal force
12
occlusal
9
finite element
8
model maxillary
8
peak von
8
von mises
8

Similar Publications

Background: Determining the distal cantilever length in All-on-Four (All-on-4) implant-supported prostheses is a major factor in the long-term success of these prostheses. The difference in mechanical properties of materials used in the fabrication of these prostheses, such as polyether ether ketone (PEEK), may have an impact on the determination of the cantilever length that best distributes stress.

Aim: To study the distribution of stress in All-on-4 mandibular prostheses in the bone, implants, and framework according to difference cantilever length in PEEK prosthetic framework using three-dimensional finite element analysis.

View Article and Find Full Text PDF

Aim: This split-mouth observational study was conducted to assess the reliability and safety of using the coronoid notch and occlusal plane as landmarks to aid surgeons during bilateral sagittal split osteotomy (BSSO).

Materials And Methods: Thirteen patients between the ages of 18 and 30 years, with class II and class III mandibular skeletal malocclusion requiring BSSO, were randomly selected and assigned to each of the study and control groups. A split-mouth study was chosen to conduct this research.

View Article and Find Full Text PDF

Biomechanical evaluation of implant options for unilateral maxillary defects: a finite element analysis.

BMC Oral Health

November 2024

Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Hacettepe University, Campus of Sıhhıye, Altındağ, Ankara, 06100, Turkey.

Objective: This study aimed to evaluate stress distribution in unilateral maxillary defects using finite element analysis (FEA) to compare subperiosteal (SI) and zygomatic implants (ZI).

Materials And Methods: A 3D model of a unilaterally atrophied maxilla was reconstructed from CT scans. Five scenarios were simulated: (1) quad zygoma implants (SC1), (2) zygoma and conventional implants (SC2), (3) two-piece SI and conventional implants (SC3), (4) one-piece SI and conventional implants (SC4) and (5) one-piece SI implant (SC5).

View Article and Find Full Text PDF

Exploring fiberglass post numbers for enhanced fatigue resistance in molars without coronary remnants.

Braz Dent J

September 2024

Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria(UFSM), Santa Maria, RS, Brazil.

This study aimed to assess the fatigue resistance of molars lacking a coronary remnant, using zero, one, two, or three fiberglass posts. Forty caries/crack-free human molars with coronal portions removed at the pulp chamber floor were randomly allocated into four groups (n=10). Following endodontic treatment, posts (Whitepost DC/DC.

View Article and Find Full Text PDF

Purpose: To assess the biomechanical advantages of combining zygoma and partial subperiosteal implants for maxillary reconstruction in severely atrophic maxillae, offering potential solutions to the challenges posed by traditional reconstruction methods.

Material And Methods: A finite element analysis used a craniofacial model simulating a totally resected maxilla. Four treatment scenarios (SCs) were evaluated: SC-1, the quad zygoma approach; SC-2, two zygoma implants (ZIs) and a one-piece subperiosteal implant (SI); SC-3, two ZI and a two-piece SI; and SC-4, four ZI and a one-piece SI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!