Direct coupling of a flow-flow electromembrane extraction probe to LC-MS.

Anal Chim Acta

Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark. Electronic address:

Published: January 2016

A fully integrated and automated electromembrane extraction LC-MS (EME-LC-MS) system has been developed and characterized. Hyphenation of a flow-flow EME probe to LC-MS was accomplished by using an in-built 10-port switching valve of the LC-MS system. The 10-port switching valve decoupled the high pressure of the UHPLC-system from the low pressure required for operation of the EME-probe by automated switching between a sample extraction/analysis and a sample load position. In the sample load position the extracted analytes were loaded into a HPLC sample loop. By switching the valve to the sample extraction/analysis position the setup allowed simultaneous analysis of previously loaded analytes while extracting a new sample. Performance of the system was characterized with respect to precision and linearity (RSD < 2.5%, R(2): 0.998) and the setup was applied for studying the in-vitro metabolism of methadone by rat liver microsomes. As the metabolic reaction proceeded, methadone and its metabolites were extracted and analyzed in parallel by LC-MS using either isocratic or gradient elution. Compared to a conventional in-vitro metabolism analysis based on protein precipitation followed by LC-MS analysis the fully automated EME-LC-MS system offers a significant time saving and in addition demonstrates increased sensitivity as the analytes were automatically enriched during the extraction process. The experiment revealed 6 to 16 times higher S/N ratios of the EME-LC-MS method compared to protein precipitation followed by LC-MS and thus concomitantly lower LOD and LOQ. The setup integrates a complete analytical workflow of rapid extraction, enrichment, separation and detection of analytes in a fully automated manner. These attributes make the developed system a powerful alternative approach for a wide range of analytical applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2015.12.014DOI Listing

Publication Analysis

Top Keywords

switching valve
12
electromembrane extraction
8
probe lc-ms
8
10-port switching
8
sample extraction/analysis
8
sample load
8
load position
8
sample
6
direct coupling
4
coupling flow-flow
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!