Time-elapsed analysis of bone is an innovative technique that uses sequential image data to analyze bone mechanics under a given loading regime. This paper presents the development of a novel device capable of performing step-wise screw insertion into excised bone specimens, within the microCT environment, whilst simultaneously recording insertion torque, compression under the screw head and rotation angle. The system is computer controlled and screw insertion is performed in incremental steps of insertion torque. A series of screw insertion tests to failure were performed (n=21) to establish a relationship between the torque at head contact and stripping torque (R(2)=0.89). The test-device was then used to perform step-wise screw insertion, stopping at intervals of 20%, 40%, 60% and 80% between screw head contact and screw stripping. Image data-sets were acquired at each of these time-points as well as at head contact and post-failure. Examination of the image data revealed the trabecular deformation as a result of increased insertion torque was restricted to within 1mm of the outer diameter of the screw thread. Minimal deformation occurred prior to the step between the 80% time-point and post-failure. The device presented has allowed, for the first time, visualization of the micro-mechanical response in the peri-implant bone with increased tightening torque. Further testing on more samples is expected to increase our understanding of the effects of increased tightening torque at the micro-structural level, and the failure mechanisms of trabeculae.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2015.12.021 | DOI Listing |
Acta Chir Orthop Traumatol Cech
January 2025
Neurochirurgická klinika Fakultní nemocnice Olomouc.
Purpose Of The Study: The annual number of spinal fusion procedures has been increasing and is well documented worldwide. The O-arm is slowly becoming the standard for transpedicular screw insertion. The accuracy and safety of this method have been confirmed by many studies.
View Article and Find Full Text PDFActa Chir Orthop Traumatol Cech
January 2025
Klinika dětské chirurgie, ortopedie a traumatologie Fakultní nemocnice Brno.
Purpose Of The Study: Temporary hemiepiphyseodesis using figure-eight plates is currently one of the main surgical techniques to correct axial deformities of lower limbs in paediatric patients. Comprehensive analysis, correct indication and monitoring of treatment are the basic prerequisites for successful therapy. The aim of the study was to analyse parameters that could become an alternative to standard parameters used nowadays, namely the inserted screw angle (SA), and a new parameter - condylar ratio (CR).
View Article and Find Full Text PDFJBJS Essent Surg Tech
January 2025
The Ohio State University College of Medicine, Columbus, Ohio.
Background: An all-inside endoscopic flexor hallucis longus (FHL) tendon transfer is indicated for the treatment of chronic, full-thickness Achilles tendon defects. The aim of this procedure is to restore function of the gastrocnemius-soleus complex while avoiding the wound complications associated with open procedures.
Description: This procedure can be performed through 2 endoscopic portals, a posteromedial portal (the working portal) and a posterolateral portal (the visualization portal).
Acta Orthop
January 2025
Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands.
Background And Purpose: This study updates 2 parallel systematic reviews and meta-analyses from 2012, which established the 1-year radiostereometric (RSA) migration thresholds for tibial components of total knee replacements (TKR) based on the risk of late revision for aseptic loosening from survival studies. The primary aim of this study was to determine the (mis)categorization rate of the 2012 thresholds using the updated review as a validation dataset. Secondary aims were evaluation of 6-month migration, mean continuous (1- to 2-year) migration, and fixation-specific thresholds for tibial component migration.
View Article and Find Full Text PDFEur Spine J
January 2025
In Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Purpose: The objective of this systematic review is to present a comprehensive summary of existing research on the use of 3D printing in spinal surgery.
Methods: The researchers conducted a thorough search of four digital databases (PubMed, Web of Science, Scopus, and Embase) to identify relevant studies published between January 1999 and December 2022. The review focused on various aspects, including the types of objects printed, clinical applications, clinical outcomes, time and cost considerations, 3D printing materials, location of 3D printing, and technologies utilized.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!