A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A new wide-angle arthroscopic system: a comparative study with a conventional 30° arthroscopic system. | LitMetric

A new wide-angle arthroscopic system: a comparative study with a conventional 30° arthroscopic system.

Knee Surg Sports Traumatol Arthrosc

Department of Orthopedic Surgery, Asan Medical Center, School of Medicine, University of Ulsan, 86 Asanbyeongwon-gil, Songpa-gu, Seoul, 138-736, Korea.

Published: May 2016

Purpose: To compare users' hand movements in performing validated shoulder arthroscopic tasks between a 30° and a wide-angle arthroscopic system, using phantom models with an optical motion analysis system.

Methods: Twelve orthopaedic residents were enrolled and randomly allocated into two groups. In order to compensate for any learning effect, a Latin square counterbalancing technique was used. An optical motion analysis system was used with markers affixed to pre-designed sites; each participant conducted four validated shoulder arthroscopic tasks using both arthroscopic systems. Each participant was instructed to perform the experiment three times with each arthroscope. The time taken, total path length, number of movements, and average acceleration were analysed.

Results: Significant differences were observed for the time taken, number of movements, and average acceleration between the two arthroscopic systems (P < 0.05 for all). However, the time taken was not significant. The mean total path length measured 53 ± 38 cm with the 30° arthroscope, while the mean with the wide-angle arthroscope was significantly shorter, at 36 ± 22 cm. The mean number of movements with the 30° and wide-angle arthroscopes were 1974 ± 1305 and 1233 ± 990, respectively, while the average accelerations were 2.6 ± 1.3 and 1.2 ± 0.6 cm/s(2), respectively. The mean time taken was 13 % faster when using the wide-angle arthroscopic system, although this was not statistically significant.

Conclusion: The wide-angle arthroscopic system improved the arthroscope manoeuvre in terms of the total path length, number of movements, and average acceleration required for experimental arthroscopy. This system may help surgeons triangulate the arthroscope and surgical instruments during surgery by expanding the field of view.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-015-3967-zDOI Listing

Publication Analysis

Top Keywords

arthroscopic system
12
wide-angle arthroscopic
8
validated shoulder
8
shoulder arthroscopic
8
arthroscopic tasks
8
optical motion
8
motion analysis
8
arthroscopic systems
8
number movements
8
movements average
8