Ultrasound-Guided Lower Cervical Nerve Root Injectate Volumes Associated With Dorsal Root Ganglion and Epidural Spread.

J Ultrasound Med

Departments of Physical Medicine and Rehabilitation (S.J.W., W.I.R., Y.J.K.) and Anatomy (U.-Y.L.), College of Medicine, Catholic University of Korea, Seoul, Korea; and Department of Physical Medicine and Rehabilitation, Korea University College of Medicine, Seoul, Korea (J.S.Y.).

Published: February 2016

AI Article Synopsis

Article Abstract

Objectives: We aimed to estimate the spread of injections for ultrasound-guided cervical nerve root blocks and to determine the optimal injectate volume required in this procedure.

Methods: A total of 32 ultrasound-guided injections (C5-C8) were made in 4 fresh cadavers. The target on each cervical root was the space between the posterior tubercle and the cervical root at the most proximal location possible on the sonogram. After ultrasound-guided needle insertion, 0.5 mL of a contrast medium was injected 4 times. The dye flow patterns were confirmed with fluoroscopy each time, and we recorded whether the contrast medium reached the dorsal root ganglion level or the epidural space. After the injections, the needle tip location was determined by computed tomography and image reconstruction.

Results: All injections produced typical neurograms. The contrast medium reached the dorsal root ganglion in 29 of 32 (90.6%) injections (mean ± SD, 0.84 ± 0.42 mL of contrast medium) and the epidural space in 10 of 32 (31.3%) injections (1.30 ± 0.54 mL of contrast medium). The mean distance between the needle tip and neural foramen was 9.64 ± 3.68 mm, and this distance correlated positively with the volume of contrast medium necessary to reach the dorsal root ganglion or the epidural space.

Conclusions: Ultrasound-guided cervical nerve root blocks show potential utility for targeting an anesthetic into the cervical root area. This study may be helpful for deciding the most appropriate volume for the procedure.

Download full-text PDF

Source
http://dx.doi.org/10.7863/ultra.15.02062DOI Listing

Publication Analysis

Top Keywords

contrast medium
24
dorsal root
16
root ganglion
16
cervical nerve
12
nerve root
12
cervical root
12
root
10
ganglion epidural
8
ultrasound-guided cervical
8
root blocks
8

Similar Publications

Objective: To evaluate Chicago Sky Blue (CSB) stain, Calcofluor white (CW) stain, and Potassium Hydroxide (KOH) mount for rapid diagnosis of dermatomycosis, using fungal culture as the gold standard.

Study Design: Cross-sectional analytical study. Place and Duration of the Study: This study was conducted in the Department of Microbiology, Armed Forces Institute of Pathology / National University of Medical Sciences, Rawalpindi, Pakistan, from July 2023 to February 2024.

View Article and Find Full Text PDF

To compare 1D (linear) tumor volume calculations and classification systems with 3D-segmented volumetric analysis (SVA), focusing specifically on their effectiveness in the evaluation and management of NF2-associated vestibular schwannomas (VS). VS were clinically followed every 6 months with cranial, thin-sliced (< 3 mm) MRI. We retrospectively reviewed and used T1-weighted post-contrast enhanced (gadolinium) images for both SVA and linear measurements.

View Article and Find Full Text PDF

Near-Field Clutter Mitigation in Speckle Tracking Echocardiography.

Ultrasound Med Biol

January 2025

Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Biomedical Engineering Programme, The University of Hong Kong, Hong Kong. Electronic address:

Objective: Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Jaundice is an indication of hyperbilirubinemia and is caused by derangements in bilirubin metabolism. It is typically apparent when serum bilirubin levels exceed 3 mg/dL and can indicate serious underlying disease of the liver or biliary tract. A comprehensive medical history, review of systems, and physical examination are essential for differentiating potential causes such as alcoholic liver disease, biliary strictures, choledocholithiasis, drug-induced liver injury, hemolysis, or hepatitis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!