Automated HEp-2 mitotic cell recognition in IIF images is an important and yet scarcely explored step in the computer-aided diagnosis of autoimmune disorders. Such step is necessary to assess the goodness of the HEp-2 samples and helps the early diagnosis of the most difficult or ambiguous cases. In this work, we propose a completely unsupervised approach for HEp-2 mitotic cell recognition that overcomes the problem of mitotic/non-mitotic class imbalance due to the limited number of mitotic cells. Our technique automatically selects a limited set of candidate cells from the HEp-2 slide and then applies a clustering algorithm to identify the mitotic ones based on their texture. Finally, a second stage of clustering discriminates between positive and negative mitoses. Experiments on public IIF images demonstrate the performance of our technique compared to previous approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2015.7320282DOI Listing

Publication Analysis

Top Keywords

hep-2 mitotic
8
mitotic cell
8
cell recognition
8
iif images
8
unsupervised hep-2
4
hep-2 mitosis
4
mitosis recognition
4
recognition indirect
4
indirect immunofluorescence
4
immunofluorescence imaging
4