Motion correction is an important component in fMRI brain image analysis. Linear registration technique is mostly used in the process based on the assumption that there is not any shape changes of human brain during imaging process. Echo planar imaging (EPI) technique has been widely adapted in fMRI imaging to shorten encoding duration and increase temporal resolution. However, due to the magnetic field inhomogeneity caused by tissues, shape distortion and signal intensity lose are brought into fMRI images by the technique. On the other hand, subject's pose in scanner has a effect on magnetic field inhomogeneity, so the EPI distortions are subject to head movement, especially when the movement is big. As a result, most current motion correction techniques, which are based on rigid registration, cannot handle the problem. In this paper, a technique that combines EPI distortion correction and motion correction to handle the above-mentioned problem is proposed. Since it is almost impossible to obtain ground truth at present, a task-related fMRI BOLD time course image with big motion is selected as experimental material to test its performance. The image is pre-processed with the proposed EPI-motion correction scheme then analyzed by FSL feat tool. Compared with another process with only motion correction and FSL feat analysis, the experimental result using the proposed method has no false activation detection. It is suggested the proposed EPI-motion correction scheme has the ability to handle the fMRI human brain images with big motion.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2015.7319624DOI Listing

Publication Analysis

Top Keywords

motion correction
20
human brain
12
big motion
12
motion
8
correction
8
fmri human
8
brain images
8
images big
8
magnetic field
8
field inhomogeneity
8

Similar Publications

Whole-body PET imaging is often hindered by respiratory motion during acquisition, causing significant degradation in the quality of reconstructed activity images. An additional challenge in PET/CT imaging arises from the respiratory phase mismatch between CT-based attenuation correction and PET acquisition, leading to attenuation artifacts. To address these issues, we propose two new, purely data-driven methods for the joint estimation of activity, attenuation, and motion in respiratory self-gated TOF PET.

View Article and Find Full Text PDF

Purpose: The long scan times of quantitative MRI techniques make motion artifacts more likely. For MR-Fingerprinting-like approaches, this problem can be addressed with self-navigated retrospective motion correction based on reconstructions in a singular value decomposition (SVD) subspace. However, the SVD promotes high signal intensity in all tissues, which limits the contrast between tissue types and ultimately reduces the accuracy of registration.

View Article and Find Full Text PDF

Purpose: Reliable image quality assessment is crucial for evaluating new motion correction methods for magnetic resonance imaging. In this work, we compare the performance of commonly used reference-based and reference-free image quality metrics on a unique dataset with real motion artifacts. We further analyze the image quality metrics' robustness to typical pre-processing techniques.

View Article and Find Full Text PDF

Removal of Subretinal Gas After Pneumatic Retinopexy Under Air Using External Manipulation.

Retin Cases Brief Rep

January 2025

The Retina Service of Wills Eye Hospital, Wills Eye Physicians-Mid Atlantic Retina, Thomas Jefferson University, Philadelphia, PA.

Purpose: To illustrate a technique for the removal of subretinal gas via pars plana vitrectomy (PPV) with air-fluid exchange and simultaneous manipulation with scleral depression.

Methods: PPV to remove subretinal gas causing persistent macula-off retinal detachment was performed in one eye, and the results were evaluated in this case report. Ports were carefully placed to avoid puncturing the retina, which was significantly displaced anteriorly past the ora serrata due to the buoyancy of the subretinal gas with the patient in a supine position.

View Article and Find Full Text PDF

Quantitative analysis of pseudo-diffusion in diffusion-weighted magnetic resonance imaging (DWI) data shows potential for assessing fetal lung maturation and generating valuable imaging biomarkers. Yet, the clinical utility of DWI data is hindered by unavoidable fetal motion during acquisition. We present IVIM-morph, a self-supervised deep neural network model for motion-corrected quantitative analysis of DWI data using the Intra-voxel Incoherent Motion (IVIM) model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!