High density multielectrode arrays (MEAs) based on CMOS technology (CMOS-MEAs) can simultaneously record extracellular spiking activity in neuronal cultures from 4096 closely spaced microelectrodes. This allows for a finer investigation of neuronal network activity compared to conventional MEAs with a few tens of electrodes. However, the sensing properties of these devices differ. To highlight this aspect, here we investigate and discuss the differences observed when quantifying spontaneous synchronized bursting events (SBEs) in datasets acquired with conventional MEAs and high-density MEAs from comparable hippocampal cultures. We found that datasets acquired with high-density MEAs exhibit collective dynamics similar to conventional arrays, but are characterized by a higher percentage of random spikes, i.e. spikes that are not part of a burst, most probably resulting from the larger recording capability. Additionally, the percentage of electrodes that record a burst is remarkably small on high-density MEAs compared to what can be observed on conventional MEAs and SBEs appear to be propagating in time across the electrode array, by involving shorter sequences of spikes per electrode. Overall, these results highlight a lower level of network synchronization involved in SBEs compared to what has been debated for several decades based on conventional MEA recordings from cell cultures.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2015.7319212DOI Listing

Publication Analysis

Top Keywords

conventional meas
12
high-density meas
12
mea recordings
8
bursting events
8
cell cultures
8
datasets acquired
8
meas
7
conventional
5
high-density
4
high-density mea
4

Similar Publications

Epithelial tissues in vitro undergo dynamic changes while differentiating heterogeneously on the culture substrate. This gives rise to diverse cellular arrangements which are undistinguished by conventional analysis approaches, such as transepithelial electrical resistance measurement or permeability assays. In this context, solid substrate-based systems with integrated electrodes and electrochemical impedance monitoring capability can address the limited spatiotemporal resolution of traditional porous membrane-based methods.

View Article and Find Full Text PDF

Photodynamic therapy (PDT) relies on the interactions between light, photosensitizers, and tissue oxygen to produce cytotoxic reactive oxygen species (ROS), primarily singlet oxygen (O) through Type II photochemical reactions, along with superoxide anion radicals (O), hydrogen peroxide (HO), and hydroxyl radicals (OH) through Type I mechanisms. Accurate dosimetry, accounting for all three components, is crucial for predicting and optimizing PDT outcomes. Conventional dosimetry tracks only light fluence rate and photosensitizer concentration, neglecting the role of tissue oxygenation.

View Article and Find Full Text PDF

PEDOT: PSS-Modified Organic Flexible and Implantable Microelectrode for Internal Bi-Directional Electrophysiology of Three-Dimensional Cardiomyocyte Spheroid.

ACS Sens

January 2025

Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China.

Three-dimensional (3D) cardiomyocyte spheroids are essential models to replicate cardiac structural and functional features in vitro. However, conventional planar and rigid microelectrode arrays (MEAs) suffer from low-quality electrophysiological recording of 3D cultures, due to limited contact areas and weak coupling between cells and MEA chips. Herein, we developed a PEDOT: PSS-modified organic flexible and implantable MEA (OFI-MEA) coupled with a self-developed integrated biosensing platform to achieve high-throughput, long-term, and stable bidirectional internal electrophysiology in 3D cardiomyocyte spheroids.

View Article and Find Full Text PDF

Ambient mass spectrometry (MS) technologies have been applied to spatial metabolomic profiling of various samples in an attempt to both increase analysis speed and reduce the length of sample preparation. Recent studies, however, have focused on improving the spatial resolution of ambient approaches. Finer resolution requires greater analysis times and commensurate computing power for more sophisticated data analysis algorithms and larger data sets.

View Article and Find Full Text PDF

Development of Simple and Rapid Bead-Based Cytometric Immunoassays Using Superparamagnetic Hybrid Core-Shell Microparticles.

ACS Meas Sci Au

December 2024

Chemical and Optical Sensing Division, Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, Berlin D-12489, Germany.

Flow cytometry-based immunoassays are valuable in biomedical research and clinical applications due to their high throughput and multianalyte capability, but their adoption in areas such as food safety and environmental monitoring is limited by long assay times and complex workflows. Rapid, simplified bead-based cytometric immunoassays are needed to make these methods viable for point-of-need applications, especially with the increasing accessibility of miniaturized cytometers. This work introduces superparamagnetic hybrid polystyrene-silica core-shell microparticles as promising alternatives to conventional polymer beads in competitive cytometric immunoassays.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!