3D UltraSound (US) probes are used in clinical applications for their ease of use and ability to obtain intra-operative volumes. In surgical navigation applications a calibration step is needed to localize the probe in a general coordinate system. This paper presents a new hand-eye calibration method using directly the kinematic model of a robot and US volume registration data that does not require any 3D localizers. First results show a targeting error of 2.34 mm on an experimental setup using manual segmentation of five beads in ten US volumes.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2015.7318251DOI Listing

Publication Analysis

Top Keywords

hand-eye calibration
8
calibration robot--ultrasound
4
robot--ultrasound probe
4
probe system
4
system localizers
4
localizers ultrasound
4
ultrasound probes
4
probes clinical
4
clinical applications
4
applications ease
4

Similar Publications

Machine Vision-Assisted Design of End Effector Pose in Robotic Mixed Depalletizing of Heterogeneous Cargo.

Sensors (Basel)

February 2025

Department of Industrial Engineering, Universidad de los Andes, Bogotá 111711, Colombia.

Automated depalletizing systems aim to offer continuous and efficient operation in warehouse logistics, reducing cycle times and contributing to worker safety. However, most commercially available depalletizing solutions are designed primarily for highly homogeneous cargo arranged in orthogonal configurations. This paper presents a real-time approach for depalletizing heterogeneous pallets with boxes of varying sizes and arbitrary orientations, including configurations where the topmost surfaces of boxes are not necessarily parallel to each other.

View Article and Find Full Text PDF

Image-based 3D reconstruction enables robot-assisted interventions and image-guided navigation, which are emerging technologies in laparoscopy. When a robotic arm guides a laparoscope for image acquisition, hand-eye calibration is required to know the transformation between the camera and the robot flange. The calibration procedure is complex and must be conducted after each intervention (when the laparoscope is dismounted for cleaning).

View Article and Find Full Text PDF

Purpose: The application of histotripsy, an emerging noninvasive, non-ionizing, and non-thermal tumor treatment, is currently limited by the inherent limitations of diagnostic ultrasound as the sole targeting modality. This study evaluates the feasibility and accuracy of cone beam computed tomography (CBCT) guidance for histotripsy treatments in an porcine model.

Materials And Methods: Histotripsy treatments were performed in the liver of seven healthy swine under the guidance of a C-arm CBCT system that was calibrated to the robotic arm of the histotripsy system.

View Article and Find Full Text PDF

The hand-eye calibration of laser profilers and industrial robots is a critical component of the laser vision system in welding applications. To improve calibration accuracy and efficiency, this study proposes a position-constrained calibration compensation algorithm aimed at optimizing the hand-eye transformation matrix. Initially, the laser profiler is mounted on the robot and used to scan a standard sphere from various poses to obtain the theoretical center coordinates of the sphere, which are then utilized to compute the hand-eye transformation matrix.

View Article and Find Full Text PDF

A universal calibration framework for mixed-reality assisted surgery.

Comput Methods Programs Biomed

February 2025

Surgical Performance Enhancement and Robotics (SuPER) Centre, Department of Surgery, McGill University, 1650 Cedar Avenue, Montreal QC H3G 1A4, Canada. Electronic address:

Background: Mixed-reality-assisted surgery has become increasingly prominent, offering real-time 3D visualization of target anatomy such as tumors. These systems facilitate translating preoperative 3D surgical plans to the patient's body intraoperatively and allow for interactive modifications based on the patient's real-time conditions. However, achieving sub-millimetre accuracy in mixed-reality (MR) visualization and interaction is crucial to mitigate device-related risks and enhance surgical precision.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!