The amorphous carbon layer (ACL), used as the hardmask for the etching of nanoscale semi-conductor materials, was etched using O2/CHF3 in addition to O2/N2 using pulsed dual-frequency capacitively coupled plasmas, and the effects of source power pulsing for different gas combinations on the characteristics of the plasmas and ACL etching were investigated. As the etch mask for ACL, a patterned SiON layer was used. The etch rates of ACL were decreased with the decrease of pulse duty percentage for both O2/N2 and O2/CHF3 due to decrease of the reactive radicals, such as F and O, with decreasing pulse duty percentage. In addition, at the same pulse duty percentage, the etch selectivity of ACL/SiON with O2/CHF3 was also significantly lower than that with O2/N2. However, the etch profiles of ACL with O2/CHF3 was more anisotropic and the etch profiles were further improved with decreasing the pulse duty percentage than those of ACL with O2/N2. The improved anisotropic etch profiles of ACL with decreasing pulse duty percentage for O2/CHF3 were believed to be related to the formation of a more effective passivation layer, such as a thick fluorocarbon layer, on the sidewall of the ACL during the etching with O2/CHF3, compared to the weak C-N passivation layer formed on the sidewall of ACL when using O2/N2.

Download full-text PDF

Source
http://dx.doi.org/10.1166/jnn.2015.11489DOI Listing

Publication Analysis

Top Keywords

pulse duty
20
duty percentage
20
decreasing pulse
12
etch profiles
12
acl
9
amorphous carbon
8
acl etching
8
profiles acl
8
anisotropic etch
8
acl o2/n2
8

Similar Publications

Background: Sleep deprivation can lead to increased body weight and blood pressure (BP), but the latent effects of partial sleep deprivation related to required night sentry duties within a short-term period on cardiometabolic characteristic changes in military personnel are unclear.

Aim: To investigate the association between night sentry duty frequency in the past 3 months and cardiometabolic characteristics in armed forces personnel.

Methods: A total of 867 armed forces personnel who were aged 18-39 years and did not take any antihypertensive medications in Taiwan in 2020 were included.

View Article and Find Full Text PDF

Background: Exercise-induced hypoalgesia (EIH) is characterized by a reduction in pain perception and sensitivity across both exercising and non-exercising body parts during and after a single bout of exercise. EIH is mediated through central and peripheral mechanisms; however, the specific effect of muscle contraction alone on EIH remains unclear. Moreover, previous studies on electrical muscle stimulation (EMS) have primarily focused on local analgesic effects, often relying on subjective pain reports.

View Article and Find Full Text PDF

The corrosion resistance of nickel-titanium nitride (Ni/TiN) composites is significantly influenced by the operation parameters during the jet pulse electrodeposition (JPE) process. The effect of current density, jet rate, TiN concentration, and duty cycle impact on the anti-corrosion property of Ni/TiN composites were investigated and optimized using the response surface method (RSM). After the optimization of the operation parameters, the corrosion current of Ni/TiN composites decreased from 9.

View Article and Find Full Text PDF

Effects of photobiomodulation on human hair dermal papilla cells with various light modes and light parameters.

J Photochem Photobiol B

December 2024

School of information science and technology, Fudan University, 2005th Songhu Rd, Shanghai 200438, China; Zhongshan Fudan Joint Innovation Center, 6th Xiangxing Rd, Zhongshan City, Guangdong Province 528403, China. Electronic address:

Androgenetic alopecia (AGA) is a prevalent hair loss disorder and influenced by genetic, hormonal, and environmental factors. Minoxidil and finasteride have been widely used for treating AGA. However, the side effects associated with these drugs often lead to poor patient compliance.

View Article and Find Full Text PDF

A Hybrid Photoplethysmography (PPG) Sensor System Design for Heart Rate Monitoring.

Sensors (Basel)

November 2024

Major of Device Science and Engineering, Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Fukuoka 8160811, Japan.

A photoplethysmography (PPG) sensor is a cost-effective and efficacious way of measuring health conditions such as heart rate, oxygen saturation, and respiration rate. In this work, we present a hybrid PPG sensor system working in a reflective mode with an optoelectronic module, i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!