Background: Diagnosis of tuberculosis (TB) remains difficult, particularly in resource-limited settings. The development of nucleic acid-based tests for detection of Mycobacterium tuberculosis complex (MTBC) has significantly increased sensitivity compared to conventional smear microscopy and provides results within a matter of hours compared to weeks for the current gold-standard, liquid culture.
Methods: In this study we performed side-by-side comparison of mycobacterial detection assays on sputum samples from 285 subjects presenting with symptoms suggestive of TB in The Gambia and a cross-sectional cohort of 156 confirmed TB patients with a median of 2 months of treatment. A novel assay, Loop-Mediated Amplification test for TB (TB-LAMP), was compared to smear microscopy, MGIT culture and GeneXpert MTB/RIF for all samples.
Results: When culture was used as the reference standard, we found an overall sensitivity for TB-LAMP of 99% (95% CI: 94.5-99.8) and specificity of 94% (95% CI: 89.3-96.7). When latent class analysis was performed, TB-LAMP had 98.6% (95% CI: 95.9-100) sensitivity and 99% (95% CI: 98.2-100) specificity compared to 91.1% (95% CI: 86.1-96) sensitivity and 100% (95% CI: 98.2-100) specificity for MGIT culture. GeneXpert had the highest sensitivity 99.1% (95% CI: 97.1-100) but the lowest specificity 96% (95% CI: 92.6-98.3). Both TB-LAMP and GeneXpert showed high sensitivity and specificity regardless of age or strain of infection.
Conclusion: Our findings show the diagnostic utility of both GeneXpert and TB-LAMP in The Gambia. Whilst TB-LAMP requires less infrastructure, it is unable to detect drug-resistant patterns and therefore would be most suitable as a screening test for new TB cases in peripheral health clinics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jinf.2015.11.011 | DOI Listing |
Background: Resource-limited settings like India need a simple, quick, and temperature-independent point-of-care diagnostic test that can diagnose tuberculous meningitis (TBM) at the earliest.
Methods: A prospective study was carried out at a tertiary care center in North India wherein 50 subjects suspected of TBM were recruited and followed up for six months between January 2019 and December 2020. The aim was to evaluate the performance of loop-mediated isothermal amplification (TB-LAMP) in diagnosing TBM as compared to a composite reference standard (CRS), mycobacteria growth indicator tube 960 (MGIT 960) culture, and GeneXpert.
Access Microbiol
November 2023
Department of Medicine, All India Institute of Medical Sciences, New Delhi, India.
Background: The rapid and accurate diagnosis of tubercular lymphadenitis remains a challenging task today. The World Health Organization (WHO) endorsed the LoopAMP MTBC kit (TB-LAMP) as a replacement for sputum smear microscopy in the diagnosis of pulmonary tuberculosis (PTB). However, no prospective diagnostic accuracy study of TB-LAMP for tubercular lymphadenitis in adults has been performed yet.
View Article and Find Full Text PDFInfect Drug Resist
January 2021
Department of Bacteriology and Immunology, Beijing Key Laboratory on Drug-Resistant Tuberculosis Research, Beijing Chest Hospital, Capital Medical University/Beijing Tuberculosis & Thoracic Tumor Research Institute, Beijing, People's Republic of China.
Objective: A prospective study was conducted to ascertain the accuracy of oral swab specimens collected in the early morning, spot and at night for detecting pulmonary tuberculosis (TB).
Methods: We prospectively enrolled patients with symptoms suggestive of pulmonary TB in Beijing Chest Hospital. An early morning sputum specimen was collected from each patient for GeneXpert MTB/RIF (Xpert) and mycobacterial culture.
Eur J Clin Microbiol Infect Dis
February 2020
Clinical Center on TB Control, Beijing Chest Hospital, Capital Medical University/Beijing Tuberculosis & Thoracic Tumor Research Institute, No 9, Beiguan Street, Tongzhou District, Beijing, 101149, People's Republic of China.
The roll-out of molecular diagnostic tools continues to be the most important shift in the tuberculosis diagnostic landscape. The aim of this study was to develop a novel external quality assessment (EQA) panels for molecular TB diagnostics. In addition, we also assessed the performance of the laboratories with the EQA panels in China.
View Article and Find Full Text PDFJ Infect
March 2016
Vaccines and Immunity Theme, Medical Research Council (MRC) Unit, Fajara, Gambia. Electronic address:
Background: Diagnosis of tuberculosis (TB) remains difficult, particularly in resource-limited settings. The development of nucleic acid-based tests for detection of Mycobacterium tuberculosis complex (MTBC) has significantly increased sensitivity compared to conventional smear microscopy and provides results within a matter of hours compared to weeks for the current gold-standard, liquid culture.
Methods: In this study we performed side-by-side comparison of mycobacterial detection assays on sputum samples from 285 subjects presenting with symptoms suggestive of TB in The Gambia and a cross-sectional cohort of 156 confirmed TB patients with a median of 2 months of treatment.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!