Rapid and Highly Accurate Prediction of Poor Loop Diuretic Natriuretic Response in Patients With Heart Failure.

Circ Heart Fail

From the Department of Internal Medicine (J.M.T., M.C., F.P.W., L.B., D.J., C.R.P.) and Program of Applied Translational Research (J.M.T., J.S., S.C., V.R., C.O., O.L., A.K., F.P.W., C.R.P.), Yale University School of Medicine, New Haven, CT; Piedmont Heart Institute, Fayetteville, GA (A.D.); and Section of Heart Failure and Cardiac Transplantation, Cleveland Clinic, OH (W.H.W.T.).

Published: January 2016

Background: Removal of excess sodium and fluid is a primary therapeutic objective in acute decompensated heart failure and commonly monitored with fluid balance and weight loss. However, these parameters are frequently inaccurate or not collected and require a delay of several hours after diuretic administration before they are available. Accessible tools for rapid and accurate prediction of diuretic response are needed.

Methods And Results: Based on well-established renal physiological principles, an equation was derived to predict net sodium output using a spot urine sample obtained 1 or 2 hours after loop diuretic administration. This equation was then prospectively validated in 50 acute decompensated heart failure patients using meticulously obtained timed 6-hour urine collections to quantify loop diuretic-induced cumulative sodium output. Poor natriuretic response was defined as a cumulative sodium output of <50 mmol, a threshold that would result in a positive sodium balance with twice-daily diuretic dosing. Following a median dose of 3 mg (2-4 mg) of intravenous bumetanide, 40% of the population had a poor natriuretic response. The correlation between measured and predicted sodium output was excellent (r=0.91; P<0.0001). Poor natriuretic response could be accurately predicted with the sodium prediction equation (area under the curve =0.95, 95% confidence interval 0.89-1.0; P<0.0001). Clinically recorded net fluid output had a weaker correlation (r=0.66; P<0.001) and lesser ability to predict poor natriuretic response (area under the curve =0.76, 95% confidence interval 0.63-0.89; P=0.002).

Conclusions: In patients being treated for acute decompensated heart failure, poor natriuretic response can be predicted soon after diuretic administration with excellent accuracy using a spot urine sample.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4741370PMC
http://dx.doi.org/10.1161/CIRCHEARTFAILURE.115.002370DOI Listing

Publication Analysis

Top Keywords

heart failure
12
sodium output
12
accurate prediction
8
loop diuretic
8
natriuretic response
8
acute decompensated
8
decompensated heart
8
diuretic administration
8
cumulative sodium
8
rapid highly
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!