Background: Combined supine-prone myocardial perfusion imaging (CSP MPI) has been shown to reduce attenuation artifact in comparison to supine-only (SU) MPI in mixed-gender populations with varying risk for coronary artery disease (CAD), often where patients served as their own controls. However, there is limited direct comparison of these imaging strategies in men.
Methods: 934 male patients underwent CSP or SU MPI. Diagnostic certainty of interpretation was compared. Within the cohort, 116 were referred for left heart catheterization (LHC) to assess for CAD. Sensitivity, specificity, and area under the curve (AUC) were compared with additional analysis based on body mass index (BMI).
Results: 597 patients completed the SU protocol and 337 patients completed the CSP protocol. Equivocal studies were seen more frequently in the SU group (13%) than in the CSP group (4%, P < .001). At catheterization, the specificity for CSP MPI of 70% was higher than 40% for SU MPI (P = .032). The CSP AUC (0.80 ± 0.06) was significantly larger than SU AUC (0.57 ± 0.05, P = .004). CSP specificity was significantly higher in obese patients.
Conclusions: CSP MPI increases diagnostic certainty and improves test accuracy for CAD detection in men with CAD risk factors, especially obese patients, compared to SU MPI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12350-015-0358-2 | DOI Listing |
Eur Radiol
December 2024
Department of Radiology, Seoul National University Hospital, Seoul National College of Medicine, Seoul, Korea.
Objectives: We investigated whether supine chest CT alone suffices for diagnosing ILAs, thereby reducing the need for prone chest CT.
Materials And Methods: Patients who underwent prone chest CT for suspected ILAs from January 2021 to July 2023, with matching supine CT within 1 year, were retrospectively evaluated. Five multinational thoracic radiologists independently rated ILA suspicion and fibrosis scores (1 to 5-point) and ILA extent (1-100%) using supine CT first, then combined supine-prone CT after a 1-month washout.
J Nucl Med Technol
December 2024
Intersocietal Accreditation Commission, Ellicott City, Maryland
The combined supine-prone imaging protocol for SPECT myocardial perfusion imaging offers significant advantages over supine imaging alone. By comparing supine and prone images, one can distinguish attenuation artifacts in the inferior and anterior walls from true perfusion defects, thus improving specificity and diagnostic accuracy. The recommended protocol is to perform prone imaging after supine stress imaging when perfusion defects are noted.
View Article and Find Full Text PDFBMC Anesthesiol
December 2022
The Department of Anesthesiology and Intensive Care Medicine, Osaka University Graduate School of Medicine, Suita, Japan.
Background: Spontaneous breathing potentially injures lungs and diaphragm when spontaneous effort is vigorous in acute respiratory distress syndrome (ARDS) while immobility also has risks of Intensive Care Unit (ICU) acquired weakness and diaphragm atrophy. Thus, ventilatory strategy to mitigate strong spontaneous effort should be promptly established without a systemic use of neuromuscular blocking agent. Here, we investigated the impacts of positive end-expiratory pressure (PEEP) and body position on the capacity of force generation from diaphragm following bilateral phrenic nerve stimulations in a rabbit ARDS model.
View Article and Find Full Text PDFFront Physiol
August 2022
University of Colorado Boulder, Ann and H.J. Smead Department of Aerospace Engineering Sciences, Boulder, CO, United States.
Entry into weightlessness results in a fluid shift and a loss of hydrostatic gradients. These factors are believed to affect the eye and contribute to the ocular changes that occur in space. We measured eye parameters during fluid shifts produced by lower body negative pressure (LBNP) and lower body positive pressure (LBPP) and changes in hydrostatic gradient direction (supine-prone) in normal subjects to assess the relative effects of fluid shifts and hydrostatic gradient changes on the eye.
View Article and Find Full Text PDFCurr Med Imaging Rev
November 2020
Medical Physics Department, Institute of Radiation Protection and Dosimetry - IRD, Brazilian Nuclear Energy Commission-CNEN, Rio de Janeiro, Brazil.
Background: Soft tissue attenuation artifacts are the most common cause of misinterpretation in myocardial perfusion Imaging (MPI). Few studies assessing the value of prone imaging in women have been published. Breast attenuation artifacts can be present in up to 40% of the MPI studies in women.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!