Fourier transform infrared spectrometer can be realized in high temperature flue gas multicomponent measurement at the same time, has wide application prospects in the field. And one of the important factors to determine the success of application, lies in the measuring system of infrared interference figure sampling phase error control. This paper discusses the main-reasons of the appearance of phase error in the system, through the analysis of Helium-neon laser interference signal zero uniformity, illustrates the produce phase error is the main reason of the laser signal and reference signal phase difference. At the meantime, the quantitative analysis of the phase error influence on instrument signal to noise ratio (SNR), also the Mertz phase correction method for the instrument improves the thousands of times of the original signal to noise ratio. And the related experiment, the experimental results show that the system based on the interference figure sampling method satisfy the needs of high temperature flue gas measurements.
Download full-text PDF |
Source |
---|
Cureus
December 2024
Private Practice, General Vascular Surgery Medical Group, Inc., San Leandro, USA.
Recent advancements in artificial intelligence (AI) have shown significant potential in the medical field, although many applications are still in the research phase. This paper provides a comprehensive review of advancements in augmented reality (AR), mixed reality (MR), and virtual reality (VR) for surgical applications from 2019 to 2024 to accelerate the transition of AI from the research to the clinical phase. This paper also provides an overview of proposed databases for further use in extended reality (XR), which includes AR, MR, and VR, as well as a summary of typical research applications involving XR in surgical practices.
View Article and Find Full Text PDFJ Chem Inf Model
January 2025
Departments of Molecular Biology and Biochemistry, Chemical and Biomolecular Engineering, Materials Science and Engineering, and Biomedical Engineering, University of California, Irvine, Irvine, California 92697, United States.
Atomic polarizabilities are considered to be fundamental parameters in polarizable molecular mechanical force fields that play pivotal roles in determining model transferability across different electrostatic environments. In an earlier work, the atomic polarizabilities were obtained by fitting them to the B3LYP/aug-cc-pvtz molecular polarizability tensors of mainly small molecules. Taking advantage of the recent PCMRESPPOL method, we refine the atomic polarizabilities for condensed-phase simulations using a polarizable Gaussian Multipole (pGM) force field.
View Article and Find Full Text PDFNat Commun
January 2025
Université de Lorraine, CNRS, Inria, LORIA, F-54000, Nancy, France.
The main obstacle to large scale quantum computing are the errors present in every physical qubit realization. Correcting these errors requires a large number of additional qubits. Two main avenues to reduce this overhead are (i) low-density parity check (LDPC) codes requiring very few additional qubits to correct errors (ii) cat qubits where bit-flip errors are exponentially suppressed by design.
View Article and Find Full Text PDFMagn Reson Imaging
January 2025
Institute of Fluid Mechanics, University of Rostock, Rostock, Germany.
Purpose: To improve the current method for MRI turbulence quantification which is the intravoxel phase dispersion (IVPD) method. Turbulence is commonly characterized by the Reynolds stress tensor (RST) which describes the velocity covariance matrix. A major source for systematic errors in MRI is the sequence's sensitivity to the variance of the derivatives of velocity, such as the acceleration variance, which can lead to a substantial measurement bias.
View Article and Find Full Text PDFNeuroimage
January 2025
Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea. Electronic address:
Magnetic resonance electrical properties tomography can extract the electrical properties of in-vivo tissue. To estimate tissue electrical properties, various reconstruction algorithms have been proposed. However, physics-based reconstructions are prone to various artifacts such as noise amplification and boundary artifact.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!