Monosubstituted lacunary Keggin [CoSiW11O39](6-) ions on graphene oxide (GO) were used in a comparative imaging study using aberration corrected transmission electron microscopy at two different acceleration voltages, 80 and 200 kV. By performing a set of static and dynamical studies, together with image simulations, we show how the use of lower voltages results in better stability and resolution of the underlying GO support while the use of higher voltages permits better resolution of the individual tungsten atoms and leads to less kinetic motion of the cluster, thus leading to a more accurate identification of cluster orientation and better stability under dynamical imaging conditions. Applying different voltages also influences the visibility of both GO and the lighter Co at lower or higher voltages, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsnano.5b05898 | DOI Listing |
Biosensors (Basel)
December 2024
Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China.
The demand for non-invasive, real-time health monitoring has driven advancements in wearable sensors for tracking biomarkers in sweat. Ammonium ions (NH) in sweat serve as indicators of metabolic function, muscle fatigue, and kidney health. Although current ion-selective all-solid-state printed sensors based on nanocomposites typically exhibit good sensitivity (~50 mV/log [NH]), low detection limits (LOD ranging from 10 to 10 M), and wide linearity ranges (from 10 to 10 M), few have reported the stability test results necessary for their integration into commercial products for future practical applications.
View Article and Find Full Text PDFBiosensors (Basel)
December 2024
Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No. 174, Shapingba Main Street, Chongqing 400030, China.
In this study, we have proposed an electrochemiluminescence (ECL) signal amplification system which is based on two-dimensional (2D) flower-like CdS@Co/Mo-MOF composites as a co-reaction accelerator of the g-CN/SO system for ultrasensitive detection of chlorpromazine hydrochloride (CPH). Specifically, the 2D flower-like Co/Mo-MOF with mesoporous alleviated the aggregation of CdS NPs while simultaneously fostering reactant-active site contact and improving the reactant-product transport rate. This allowed the material to act as a novel co-reaction accelerator, speeding up the transformation of the SO into SO and enhancing the cathodic ECL emission of g-CN.
View Article and Find Full Text PDFJ Hazard Mater
December 2024
Department of Civil, Construction and Environmental Engineering, San Diego State University, 5500 Campanile Drive, San Diego, CA 92182, USA.
Highly toxic halo-/nitro-substituted organics, often in low concentrations and with high hydrophobicity, make it difficult to obtain electrons for reduction when strongly electron-competing substances (e.g., O, H/HO, NO) coexist.
View Article and Find Full Text PDFSe Pu
January 2025
State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
17-Estradiol (E2) is a natural steroidal estrogen essential for a variety of physiological functions in organisms. However, external E2, which is renowned for its potent biological effects, is also considered to be an endocrine-disrupting compound (EDC) capable of disturbing the normal operation of the endocrine system, even at nanogram-per-liter (ng/L) concentrations. Studies have revealed that medical and livestock wastewater can be contaminated with E2, which poses potential risks to human health.
View Article and Find Full Text PDFAnal Chem
December 2024
Department of Chemistry, National Chung Hsing University, Taichung City 402202, Taiwan, ROC.
Four-dimensional printing (4DP) technologies can expand the functionality of stimuli-responsive devices to enable the integration of multiple stimuli-responsive parts into a compact device. Herein, we used digital light processing three-dimensional printing technique, flexible photocurable resins, and photocurable resins of the temperature-responsive hydrogels comprising -isopropylacrylamide (NIPAM), ,'-methylenebis(acrylamide) (MBA), and graphene for 4DP of a lab-on-valve (LOV) solid-phase extraction (SPE) device. This device featured flow manifolds and a monolithic packing connected by four near-infrared (NIR)-actuated temperature-responsive switching valves composed of a poly(NIPAM/MBA) (PNM) ball pushing a flexible membrane.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!