Long-Term Hemodynamic Performance of the Aortic Valve After David I: An Echocardiographic Study.

Semin Thorac Cardiovasc Surg

Cardiac Surgery Unit, AOU Policlinico-Vittorio Emanuele, Ferrarotto Hospital, University of Catania, Catania, Italy. Electronic address:

Published: October 2016

Despite optimal hemodynamics at rest, the performance of the aortic valve under stress conditions long after David I procedure is still debated. From 2001-2014, 73 patients underwent reimplantation with David I technique. Aortic valve function of 13 patients (age 61.2 ± 8.72) with a follow-up of at least 5 years (6.3 ± 0.9 years) was assessed at exercise echocardiographic stress test on a stationary cycle. Patients who had undergone concomitant procedure, with recurrent aortic insufficiency or mitral valve incompetence, were excluded. In all, 8 healthy volunteers served as controls. Transvalvular gradients progressively increased during the steps in both groups (P-within < 0.001), being higher in David patients (P-between < 0.001), but never reaching a clinical significance (David Peak gradient 23.8 ± 9.3 mmHg; Mean gradient 13.2 ± 5.1 mmHg). Effective orifice area (EOA) and EOA index did not change during the test in David patients, whereas Controls showed a progressive increase of functional valve area to a peak at 50 W (Controls EOA 4.0 ± 0.5 cm(2); EOA index 2.0 ± 0.3 cm(2)/m(2)). In conclusion, David I procedure ensures good hemodynamics during high-flow conditions at long-term follow-up. The reimplantation of the functional aortic annulus inside a rigid tube determines a paradoxical reduction of functional aortic valve area, secondary to the increased stroke volume, without any clinically relevant increase in transvalvular gradients. These data confirm the reliability of David I in the long term, even under physical stress conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.semtcvs.2015.06.011DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
performance aortic
8
david
8
stress conditions
8
david procedure
8
transvalvular gradients
8
david patients
8
valve area
8
functional aortic
8
aortic
6

Similar Publications

: New-onset postoperative atrial fibrillation (POAF) is the most common complication after cardiac surgery, occurring approximately in one-third of the patients. This study considered all-comer patients who underwent cardiac surgery to build a predictive model for POAF. : A total of 3467 (Center 1) consecutive patients were used as a derivation cohort to build the model.

View Article and Find Full Text PDF

Paravalvular leak (PVL) was initially recognized as one of the most common complications after transcatheter aortic valve implantation (TAVI) and has been linked to adverse clinical outcomes, including mortality. This study aims to assess the long-term clinical effects of PVL in patients undergoing TAVI with the latest generation of transcatheter aortic valves, as part of the national observational prospective multicenter study OBSERVANT II. OBSERVANT II included all consecutive patients with severe aortic stenosis who underwent TAVI across 28 Italian centers from December 2016 to September 2018.

View Article and Find Full Text PDF

Previous studies evaluated the prognostic role of hematological parameters in predicting outcome in patients with infective endocarditis (IE). However, only a few studies evaluated the role of hematological parameters in patients undergoing surgery for IE. The aim of this study was to review our 20-year experience with the treatment of native (NVE) and prosthetic (PVE) valve endocarditis and to evaluate the role of neutrophil-to-lymphocyte ratio (NLR), neutrophil-to-platelet ratio (NPR), platelet-to-lymphocyte ratio (PLR), monocyte-to-lymphocyte ratio (MLR), neutrophil-to monocyte ratio (NMR), and systemic inflammatory index (SII) on early and long-term outcomes of patients undergoing surgery for NVE and PVE.

View Article and Find Full Text PDF

Stuck prosthetic valves, often resulting from pannus formation or thrombus accumulation, represent a critical complication in prosthetic valve management, carrying significant risks for morbidity and mortality. This study aims to identify factors associated with stuck valve development and assess the effectiveness of interventions in restoring normal valve function. A total of 27 patients with stuck valves were analyzed, including mitral, aortic, and tricuspid valve cases.

View Article and Find Full Text PDF

Myocardial work (MW) is a new echocardiographic parameter used in the assessment of cardiac energy expenditure. The aim of the current study was to evaluate changes in left ventricular MW parameters in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). One hundred and thirty five consecutive patients who underwent TAVI at one center were evaluated before and after the procedure using transthoracic echocardiography (TTE) to assess the following MW indices: global constructive work (GCW), global wasted work (GWW), global work index (GWI) and global work efficiency (GWE).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!