A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Functional polyethersulfone particles for the removal of bilirubin. | LitMetric

Functional polyethersulfone particles for the removal of bilirubin.

J Mater Sci Mater Med

College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, 610065, People's Republic of China.

Published: February 2016

In this study, polyethersulfone/poly (glycidyl methacrylate) particles are prepared via in situ cross-linked polymerization coupled with a phase inversion technique. The surfaces of these particles are then further modified by grafting amino groups using tetraethylenepentamine, dethylenetriamine, ethylenediamine, or 1,6-hexanediamine for the removal of bilirubin. The particles are characterized by Flourier transform infrared spectroscopy, thermogravimetric analysis, and scanning electron microscopy. Batch adsorption experiments are performed to verify the adsorption capability, and the effect of bilirubin initial concentration, bovine serum albumin concentration, and solution ionic strength on the adsorption is also investigated. In addition, both adsorption kinetic and isotherm models are applied to analyze the adsorption process of bilirubin, and a particle column is used to further study the bilirubin removal ability.To prove that the method was a universal portal to prepare functional particles, polysulfone, polystyrene, and poly(vinylidene fluoride) based functional particles were also prepared and used for the removal of bilirubin. This study and the results indicated that the particles had a great potential to be used in hemoperfusion treatment for hyperbilirubinemia.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10856-015-5642-9DOI Listing

Publication Analysis

Top Keywords

removal bilirubin
12
bilirubin study
8
particles prepared
8
functional particles
8
particles
7
bilirubin
6
adsorption
5
functional polyethersulfone
4
polyethersulfone particles
4
removal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!