A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiosynthesis of clinical doses of ⁶⁸Ga-DOTATATE (GalioMedix™) and validation of organic-matrix-based ⁶⁸Ge/⁶⁸Ga generators. | LitMetric

AI Article Synopsis

  • 68Ga-DOTATATE is a peptide-based radiolabeled agent designed to target somatostatin receptors found in neuroendocrine tumors, and the study focuses on validating an organic matrix generator for its production.
  • The manual synthesis process involves using 68Ga with a high radiochemical yield of 99%, with quality control measures ensuring the safe and effective preparation of clinical doses in about 35 minutes.
  • The findings highlight that the 68Ga labeling process is efficient and does not require additional purification steps, making it suitable for clinical use and contributing to the growing interest in 68Ga-labeled agents in patient care.

Article Abstract

Introduction: 68Ga-DOTATATE is a radiolabeled peptide-based agonist that targets somatostatin receptors overexpressed in neuroendocrine tumors. Here, we present our results on validation of organic matrix 68Ge/68Ga generators (ITG GmbH) applied for radiosynthesis of the clinical doses of 68Ga-DOTATATE (GalioMedixTM).

Methods: The clinical grade of DOTATATE (25 μg±5 μg) compounded in 1 M NaOAc at pH=5.5 was labeled manually with 514±218 MBq (13.89±5.9 mCi) of 68Ga eluate in 0.05 N HCl at 95°C for 10 min. The radiochemical purity of the final dose was validated using radio-TLC. The quality control of clinical doses included tests of their osmolarity, endotoxin level, radionuclide identity, filter integrity, pH, sterility and 68Ge breakthrough.

Results: The final dose of 272±126 MBq (7.35±3.4 mCi) of 68Ga-DOTATATE was produced with a radiochemical yield (RCY) of 99%±1%. The total time required for completion of radiolabeling and quality control averaged approximately 35 min. This resulted in delivery of 50%±7% of 68Ga-DOTATATE at the time of calibration (not decay corrected).

Conclusions: 68Ga eluted from the generator was directly applied for labeling of DOTA-peptide with no additional pre-concentration or pre-purification of isotope. The low acidity of 68Ga eluate allows for facile synthesis of clinical doses with radiochemical and radionuclide purity higher than 98% and average activity of 272±126 MBq (7.3±3 mCi). There is no need for post-labeling C18 Sep-Pak purification of final doses of radiotracer. Advances in knowledge and implications for patient care. The clinical interest in validation of 68Galabeled agents has increased in the past years due to availability of generators from different vendors (Eckert-Ziegler, ITG, iThemba), favorable approach of U.S. FDA agency to initiate clinical trials, and collaboration of U.S. centers with leading EU clinical sites. The list of 68Ga-labeled tracers evaluated in clinical studies should growth because of the sensitivity of PET technique, the simplicity of the shakebake approach for the dose preparation and reliability of 68Ge/68Ga generators. Our studies have confirmed the reproducible elution profile, and high reliability of ITG GmbH generators required for routine doses preparation according to FDA recommendations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5538886PMC
http://dx.doi.org/10.1016/j.nucmedbio.2015.08.004DOI Listing

Publication Analysis

Top Keywords

clinical doses
16
radiosynthesis clinical
8
68ge/68ga generators
8
itg gmbh
8
clinical
8
68ga eluate
8
final dose
8
quality control
8
272±126 mbq
8
doses
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!