[Effect of thermal cycling on the composite- composite repair bond strength].

Zhonghua Kou Qiang Yi Xue Za Zhi

Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology, Beijing 100081, China; Email:

Published: August 2015

Objective: To evaluate the effect of aging of the composite and the adhesive interface on composite-composite repair bond strength.

Methods: Methacrylate-based composite resin (Clearfil AP-X, composite A) and silorane-based composite resin (Filtek P90, composite B) and their corresponding adhesive, Clearfil SE Bond (adhesive a) and Filtek P90 System Adhesive (adhesive b), were selected in this study. Twenty-four substrates were prepared from composite A or B separately and divided into three groups, each group had 8 substrates: group one, new composites were adhered to the substrates with the use of adhesive a or b, followed by cutting the blocks into sticks; group two, new composites were adhered to the substrates using adhesive a or b, followed by cutting into sticks and thermal cycling; group three, substrates were thermocycled, then polished and adhered new composites using adhesive a or b, followed by cutting into sticks. Each group had 8 combinations of substrate(A, B)-adhesive(a, b)-repair composite (A, B). Fifteen sticks without flaws in each combination of 3 groups were selected utilizing stereomicroscope. The data were analyzed by independent samples t test.

Results: In group two, the microtensile strength(MS) of combinations using adhesive a and composite A or B to repair [A-a-A: (45.0 ± 3.2) MPa, B-a-A: (41.7 ± 3.3) MPa, A-a-B: (28.6 ± 3.9) MPa, B-a-B: (47.7 ± 6.6) MPa], and using adhesive b and composite A to repair [A-b-A: (44.2 ± 4.7) MPa, B-b-A: (38.0 ± 3.2) MPa] decreased significantly compared with corresponding combinations in group 1[A-a-A: (70.7 ± 5.5) MPa, B-a-A: (60.3 ± 5.1) MPa, A-a-B: (44.2 ± 1.6) MPa, B-a-B: (54.1 ± 3.2) MPa, A-b-A: (65.6 ± 7.2) MPa, B-b-A: (59.1 ± 4.1) MPa] (P<0.05). However, there was no significant difference between the MS of combinations using adhesive b and composite B to repair in group one and the MS of combinations in group two (P>0.05). The MS of all combinations in group three decreased significantly (P<0.05).

Conclusions: Aging of the composite and the adhesive interface might affect the composite-composite repair bond strength.

Download full-text PDF

Source

Publication Analysis

Top Keywords

composite repair
12
adhesive cutting
12
composite
10
adhesive
10
mpa
9
thermal cycling
8
repair bond
8
composite resin
8
filtek p90
8
group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!