Cone-beam CTs (CBCTs) installed on a linear accelerator can be used to provide fast and accurate automatic six degrees of freedom (6DoF) vector displacement information of the patient position just prior to radiotherapy. These displacement corrections can be made with 6DoF couches, which are primarily used for patient setup correction during stereotactic treatments. When position corrections are performed daily prior to treatment, the correction is deemed "online". However, the interface between the first generation 6DoF couches and the imaging software is suboptimal. The system requires the user to select manually the patient and type the match result by hand. The introduction of 6DoF setup correction for treatments, other than stereotactic radiotherapy, is hindered by both the high workload associated with the online protocol and the interface issues. For these reasons, we developed software that fully integrates the 6DoF couch with the linear accelerator. To further reduce both the workload and imaging dose, three off-line 6DoF correction protocols were analyzed. While the protocols require significantly less imaging, the analysis assessed their ability to reduce the systematic rotation setup correction. CBCT scans were acquired for 19 patients with intracranial meningioma. The total number of CBCT scans was 856, acquired before and after radiotherapy treatment fractions. The patient positions were corrected online using a 6DoF robotic couch. The effects on the residual rotational setup error for three off-line protocols were simulated. The three protocols used were two known off-line protocols, the no action level (NAL) and the extended no action level (eNAL), and one new off-line protocol (eNAL++). The residual setup errors were compared using the systematic and random components of the total setup error. The reduction of the rotational setup error of these protocols was optimized with respect to the required workload (i.e., number of CBCTs required). Rotational errors up to 3.2° were found after initial patient setup. The eNAL++ protocol achieved a reduction of the systematic rotational setup error similar to that of the online protocol (pitch from 0.8° to 0.3°), while requiring 70% fewer CBCTs. With a 6DoF robotic couch, translation, and rotation patient position corrections can be performed off-line to reduce the systematic setup error, workload, and patient scan dose.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690996PMC
http://dx.doi.org/10.1120/jacmp.v16i6.5583DOI Listing

Publication Analysis

Top Keywords

setup error
20
rotational setup
16
robotic couch
12
setup correction
12
setup
11
setup errors
8
linear accelerator
8
6dof
8
patient position
8
6dof couches
8

Similar Publications

A preliminary study was conducted using electronic portal imaging device (EPID) based dose verification in pre-treatment and in vivo dose reconstruction modes for breast cancer intensity-modulated radiation therapy (IMRT) technique with known repositioning set-up errors. For 43 IMRT plans, the set-up errors were determined from 43 sets of EPID images and 258 sets of cone beam computed tomography images. In-house developed Edose software was used to reconstruct the dose distribution using the pre-treatment and on-treatment (in vivo) EPID acquired fluence maps.

View Article and Find Full Text PDF

A (target) quantum system is often measured through observations performed on a second (meter) system to which the target is coupled. In the presence of global conservation laws holding on the joint meter-target system, the Wigner-Araki-Yanase theorem and its generalizations predict a lower bound on the measurement's error (Ozawa's bound). While practically negligible for macroscopic meters, it becomes relevant for microscopic ones.

View Article and Find Full Text PDF

The rapid advancement of quantum key distribution technology in recent years has spurred significant innovation within the field. Nevertheless, a crucial yet frequently underexplored challenge involves the comprehensive evaluation of security quantum state modulation. To address this issue, we propose a novel framework for quantum group key distribution.

View Article and Find Full Text PDF

Waveguide evanescent field fluorescence microscopy (WEFF) is an evanescent-based microscopy that utilizes a confined thin film of light, around 100 nm, to image the plasma membrane of cells attached to a waveguide. Low photobleaching and low background besides its high axial resolution allows time-lapse imaging to investigate changes in cell morphology in the presence or absence of chemical agents. Both large field of view (FOV) and uniform illumination are very important while imaging cell-substrate contacts with an evanescent field.

View Article and Find Full Text PDF

Advancing characterization of pyrolysis products: Comprehensive gas chromatography methods for analytes in gas and liquid phases.

J Chromatogr A

December 2024

Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta, Canada T6G 2P5. Electronic address:

The development of biofuel technologies depends on the accurate identification and quantification of products from the conversion processes. Given the complexity of the renewable resources, the availability of biomass, and the versatility of conversion methods, there is a need for characterization methods that provide rapid and reliable analysis for various products coming from different conversion processes with minimal sample preparation. This study develops and validates gas chromatography methods that use multiple detectors to analyze pyrolytic compounds in both gas and liquid phases efficiently in a single, rapid run.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!