The purpose of this study was to retrospectively investigate the accuracy, plan quality, and efficiency of using intensity-modulated arc therapy (IMAT) for whole brain radiotherapy (WBRT) patients with sparing not only the hippocampus (following RTOG 0933 compliance criteria) but also other organs at risk (OARs). A total of 10 patients previously treated with nonconformal opposed laterals whole-brain radiotherapy (NC-WBRT) were retrospectively replanned for hippocampal sparing using IMAT treatment planning. The hippocampus was volumetrically contoured on fused diagnostic T1-weighted MRI with planning CT images and hippocampus avoidance zone (HAZ) was generated using a 5 mm uniform margin around the hippocampus. Both hippocampi were defined as one paired organ. Whole brain tissue minus HAZ was defined as the whole-brain planning target volume (WB-PTV). Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5 mm leaf width at isocenter) and 6 MV beam for a prescription dose of 30 Gy in 10 fractions following RTOG 0933 dosimetric criteria. Two full coplanar arcs with orbits avoidance sectors were used. In addition to RTOG criteria, doses to other organs at risk (OARs), such as parotid glands, cochlea, external/middle ear canals, skin, scalp, optic pathways, brainstem, and eyes/lens, were also evaluated. Subsequently, dose delivery efficiency and accuracy of each IMAT plan was assessed by delivering quality assurance (QA) plans with a MapCHECK device, recording actual beam-on time and measuring planed vs. measured dose agreement using a gamma index. On IMAT plans, following RTOG 0933 dosimetric criteria, the maximum dose to WB-PTV, mean WB-PTV D2%, and mean WB-PTV D98% were 34.9 ± 0.3 Gy, 33.2 ± 0.4 Gy, and 26.0± 0.4Gy, respectively. Accordingly, WB-PTV received the prescription dose of 30Gy and mean V30 was 90.5% ± 0.5%. The D100%, and mean and maximum doses to hippocampus were 8.4 ± 0.3 Gy, 11.2 ± 0.3 Gy, and 15.6 ± 0.4 Gy, on average, respectively. The mean values of homogeneity index (HI) and conformity index (CI) were 0.23 ± 0.02 and 0.96 ± 0.02, respectively. The maximum point dose to WB-PTV was 35.3 Gy, well below the optic pathway tolerance of 37.5 Gy. In addition, compared to NC-WBRT, dose reduction of mean and maximum of parotid glands from IMAT were 65% and 50%, respectively. Ear canals mean and maximum doses were reduced by 26% and 12%, and mean and maximum scalp doses were reduced by 9 Gy (32%) and 2 Gy (6%), on average, respectively. The mean dose to skin was 9.7 Gy with IMAT plans compared to 16 Gy with conventional NC-WBRT, demonstrating that absolute reduction of skin dose by a factor of 2. The mean values of the total number of monitor units (MUs) and actual beam on time were 719 ± 44 and 2.34 ± 0.14 min, respectively. The accuracy of IMAT QA plan delivery was (98.1 ± 0.8) %, on average, with a 3%/3 mm gamma index passing rate criteria. All of these plans were considered clinically acceptable per RTOG 0933 criteria. IMAT planning provided highly conformal and homogenous plan with a fast and effective treatment option for WBRT patients, sparing not only hippocampi but also other OARs, which could potentially result in an additional improvement of the quality life (QoL). In the future, we plan to evaluate the clinical potential of IMAT planning and treatment option with hippocampal and other OARs avoidance in our patient's cohort and asses the QoL of the WBRT patients, as well as simultaneous integrated boost (SIB) for the brain metastases diseases.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690185 | PMC |
http://dx.doi.org/10.1120/jacmp.v16i5.5587 | DOI Listing |
Radiother Oncol
December 2024
Department of Radiation Oncology, Corewell Health-East, Royal Oak, MI, United States. Electronic address:
Purpose: To validate a CT-based deep learning (DL) hippocampal segmentation model trained on a single-institutional dataset and explore its utility for multi-institutional contour quality assurance (QA).
Methods: A DL model was trained to contour hippocampi from a dataset generated by an institutional observer (IO) contouring on brain MRIs from a single-institution cohort. The model was then evaluated on the RTOG 0933 dataset by comparing the treating physician (TP) contours to blinded IO and DL contours using Dice and Haussdorf distance (HD) agreement metrics as well as evaluating differences in dose to hippocampi when TP vs.
Radiat Environ Biophys
August 2024
División de Oncología y Uronefrología, Departamento de Radioterapia, Unidad Médica de Alta Especialidad, Hospital de Especialidades del Centro Médico Nacional "Ignacio García Téllez", Instituto Mexicano del Seguro Social, Mérida Yucatán, CP 97150, México.
This study aimed to evaluate the modulated arc therapy (mARC) technique as a planning and treatment option for hippocampal sparing whole brain radiotherapy (HS-WBRT) following the Radiation Therapy Oncology Group (RTOG) 0933 dosimetric criteria. Computed tomography (CT) and magnetic resonance imaging (MRI) were selected retrospectively for 15 patients. Two types of plans were created for each patient, namely an intensity-modulated radiation therapy (IMRT) and a mARC plan.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2024
Department of Neurosurgery, University Clinical Center, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-752 Katowice, Poland.
Brain metastases (BMs) pose significant clinical challenges in systemic cancer patients. They often cause symptoms related to brain compression and are typically managed with multimodal therapies, such as surgery, chemotherapy, whole brain radiotherapy (WBRT), and stereotactic radiosurgery (SRS). With modern oncology treatments prolonging survival, concerns about the neurocognitive side effects of BM treatments are growing.
View Article and Find Full Text PDFRadiat Environ Biophys
March 2024
Department of Radiation Oncology, Max Super Specialty Hospital, Ghaziabad, 201010, India.
To compare treatment planning and dosimetric outcomes for hippocampal sparing whole brain radiotherapy (WBRT) with the simultaneous integrated boost (SIB) in brain metastasis (BM) patients using tumour control probability (TCP) and normal tissue complication probability (NTCP) formalism between IMRT, VMAT, and HT techniques. In this retrospective study, the treatment data of 20 BM patients who typically received whole brain radiation with SIB treatment were used. Prescription doses of 30 Gy and 36 Gy was delivered in 10 fractions for WBRT and SIB, respectively.
View Article and Find Full Text PDFMed Dosim
May 2024
Department of Radiation Oncology, Chinese Academy of Medical Sciences, Peking Union Medical College Hospital, Beijing, China. Electronic address:
Whole brain radiation therapy with hippocampal-sparing (HS-WBRT) is a novel treatment of brain metastases, which can relieve symptoms reduce recurrence in the central nervous system, and spare the hippocampus without compromising target coverage. This study aims to find out the superior combination of the treatment planning system and linear accelerator between Eclipse (version 15.6) with TrueBeam and uRT-TPOIS (vision R001.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!