Implant fracture under dynamic fatigue loading: influence of embedded angle and depth of implant.

Odontology

Department of Crown and Bridge Prosthodontics, The Nippon Dental University School of Life Dentistry at Niigata, Hamaura-chou 1-8, Chuuou-ku, Niigata, 951-8580, Japan.

Published: September 2016

The purpose of this study was to investigate the relationship between implant fracture under cyclic-fatigue loading at different embedding angles, embedding depths, and loading forces. Twenty-four cylinder-type implants 3.3 mm in diameter and 10 mm in length were used. Test specimens were 30 mm(3) resin blocks with one surfaces inclined at angles of either 5°, 10°, 15° and 20° and embedded vertically with implants at depths of either 5 or 10 mm to the these surfaces. A straight abutment was connected to the implant and cut to 5 mm in length, and a hemispherical crown 5 mm in diameter and 7 mm in length was cast with a 12 % gold-silver-palladium alloy and cemented onto the abutment. Each specimen was mounted onto a fatigue loading device to apply repeated vertical loads of 294, 392, and 490 N to the coronal edge of the crown 60 times per min until reaching 100,000 cycles. For each respective specimen, we recorded the combined conditions of embedding and loading forces and the number of loading cycles until fracture, and then observed the fracture sites microscopically. The number of loading cycles until implant fracture tended to decrease in proportion to increased loading forces and embedded angles, and decreased embedded depths. Implant fracture was observed at angles of inclination over 10°. For specimens with an implant embedded at a depth of 5 mm, almost all fractures occurred at the center of the implant body; however, for those embedded at a depth of 10 mm, fractures occurred at the interface between the implant body and the abutment. These results demonstrate that implant fracture is associated with the loading axis, the amount of loading, and the embedded depth of the implant.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10266-015-0228-zDOI Listing

Publication Analysis

Top Keywords

implant fracture
20
loading forces
12
embedded depth
12
implant
11
loading
10
fatigue loading
8
depth implant
8
number loading
8
loading cycles
8
fracture observed
8

Similar Publications

Introduction: Regional anesthesia increases in popularity in orthopaedic surgery. It is usually applied in elective surgeries of the extremities. The aim of this study was to assess indication of the use of general anesthesia in the surgical treatment of distal radius fractures.

View Article and Find Full Text PDF

Finite element investigation for improving chest wall reconstruction process using ceramic and polymeric implants.

Sci Rep

January 2025

Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt.

Car accidents, infections caused by bacteria or viruses, metastatic lesions, tumors, and malignancies are the most frequent causes of chest wall damage, leading to the removal of the affected area. After excision, artificial bone or synthetic materials are used in chest wall reconstruction to restore the skeletal structure of the chest. Chest implants have traditionally been made from metallic materials like titanium alloys due to their biocompatibility and durability.

View Article and Find Full Text PDF

CORR Insights®: What Factors Are Associated With Implant Revision in the Treatment of Pathologic Subtrochanteric Femur Fractures?

Clin Orthop Relat Res

December 2024

Orthopedic Surgeon, Department of Orthopedic Surgery and Sports Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, the Netherlands.

View Article and Find Full Text PDF

Orthopedic surgery and traumatology necessitate cost-effective approaches that can be replicated across multiple venues. Finite Element (FE) simulation models have evolved as a solution, allowing for consistent investigations into biomechanical systems. Finite Element Analysis (FEA), which began in the 1950s aviation industry, has since expanded into orthopedics.

View Article and Find Full Text PDF

Dental implant in esthetic zone: A case report.

SAGE Open Med Case Rep

January 2025

PhD in Health Science Program, Faculty of Medicine, Mahasarakham University, Mahasarakham, Thailand.

This case report emphasizes the complexities involved in dental implant placement within the anterior esthetic zone, focusing on the integration of advanced surgical techniques and meticulous prosthetic design for optimal esthetic and functional results. A 28-year-old male presented with the absence of the upper left central incisor, which had been extracted 5 years prior due to fracture. Clinical and radiographic assessments indicated normal alveolar bone levels; however, the esthetic demands required a specialized approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!