Computational fluid dynamics (CFD) can have a complementary predictive role alongside the exquisite visualization capabilities of 4D cardiovascular magnetic resonance (CMR) imaging. In order to exploit these capabilities (e.g., for decision-making), it is necessary to validate computational models against real world data. In this study, we sought to acquire 4D CMR flow data in a controllable, experimental setup and use these data to validate a corresponding computational model. We applied this paradigm to a case of congenital heart disease, namely, transposition of the great arteries (TGA) repaired with arterial switch operation. For this purpose, a mock circulatory loop compatible with the CMR environment was constructed and two detailed aortic 3D models (i.e., one TGA case and one normal aortic anatomy) were tested under realistic hemodynamic conditions, acquiring 4D CMR flow. The same 3D domains were used for multi-scale CFD simulations, whereby the remainder of the mock circulatory system was appropriately summarized with a lumped parameter network. Boundary conditions of the simulations mirrored those measured in vitro. Results showed a very good quantitative agreement between experimental and computational models in terms of pressure (overall maximum % error = 4.4% aortic pressure in the control anatomy) and flow distribution data (overall maximum % error = 3.6% at the subclavian artery outlet of the TGA model). Very good qualitative agreement could also be appreciated in terms of streamlines, throughout the cardiac cycle. Additionally, velocity vectors in the ascending aorta revealed less symmetrical flow in the TGA model, which also exhibited higher wall shear stress in the anterior ascending aorta.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4677094PMC
http://dx.doi.org/10.3389/fped.2015.00107DOI Listing

Publication Analysis

Top Keywords

cardiovascular magnetic
8
magnetic resonance
8
validate computational
8
computational fluid
8
fluid dynamics
8
computational models
8
cmr flow
8
mock circulatory
8
tga model
8
ascending aorta
8

Similar Publications

Background: It remains unclear whether the newly adopted high-power, short-duration (HP-SD) setting in ablation for atrial fibrillation (AF) impacts periprocedural thrombotic markers or silent stroke (SS) onset.

Objective: The aim of the present study was to investigate the clinical impact of HP-SD setting ablation on changes in periprocedural thrombotic markers and the onset of SS.

Methods: We enrolled 101 AF patients: the HP-SD group (n = 67) using 50 W and the conventional ablation group (n = 34) using 30 to 40 W.

View Article and Find Full Text PDF

Myocardial Abnormalities Across the AHA/ACC Stages of Heart Failure in Patients With Diabetes.

JACC Asia

December 2024

Departments of Magnetic Resonance Imaging, Fuwai Hospital, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Background: Cardiac magnetic resonance imaging (CMR) could serve as a robust tool for comprehensive evaluation of early changes across heart failure (HF) stages classified by the American Heart Association/American College of Cardiology guideline in diabetes mellitus (DM).

Objectives: The authors aimed to explore phenotypic imaging features characterizing DM participants at different HF stages by CMR.

Methods: DM participants with preserved ejection fraction who underwent CMR examination between January 2020 and December 2021 were evaluated.

View Article and Find Full Text PDF

Background: Right ventricular restrictive physiology (RVRP) is a common occurrence in repaired tetralogy of Fallot (rTOF). The relationship of RVRP with biventricular blood flow components and kinetic energy (KE) from 4-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is unclear.

Objectives: The purpose of this study was to investigate the association of 4D flow CMR parameters with RVRP in rTOF patients.

View Article and Find Full Text PDF

Atherosclerosis is the leading cause of cardiovascular disease and myocardial infarction. Precise and effective plaque targeting is a major objective for therapeutic outcomes throughout various stages of atherosclerosis. Inspired by the natural recruitment of neutrophils in atherosclerotic plaques, we fabricated a simvastatin (ST)-loaded and neutrophil membrane-cloaked nanoplatform (NNP) for enhancing localized payload delivery and atherosclerosis management.

View Article and Find Full Text PDF

Cardiac masses encompass a diverse range of benign and malignant tumors as well as pseudotumors. Accurate histologic identification is essential for guiding appropriate treatment, yet the diagnostic process remains challenging. Although biopsy is traditionally the diagnostic gold standard, its invasive nature and associated risks limit its application.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!