A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of lead in biomass and products of the pyrolysis process by direct solid or liquid sample analysis using HR-CS GF AAS. | LitMetric

Determination of lead in biomass and products of the pyrolysis process by direct solid or liquid sample analysis using HR-CS GF AAS.

Talanta

Instituto de Química, Universidade Federal do Rio Grande do Sul, 91501-970 Porto Alegre, RS, Brazil; Instituto Nacional de Ciência e Tecnologia do CNPq - INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA, Brazil. Electronic address:

Published: September 2016

A method has been developed for the determination of lead in biomass, bio-oil, pyrolysis aqueous phase, and biomass ashes by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) and direct solid or liquid sample analysis. All measurements were performed without chemical modifier and calibration could be carried out using aqueous standard solutions. A pyrolysis temperature of 800°C and an atomization temperature of 2200°C were applied. The limits of detection and quantification were, respectively, 0.5 µg kg(-1) and 2 µg kg(-1) using the analytical line at 217.001 nm and 6 µg kg(-1) and 19 µg kg(-1) at 283.306 nm. The precision, expressed as relative standard deviation, was between 3% and 10%, which is suitable for direct analysis. The lead concentrations found for the solid samples varied between 0.28 and 1.4 mg kg(-1) for biomass and between 0.25 and 2.3 mg kg(-1) for ashes, these values were much higher than those found for bio-oil (2.2-16.8 µg kg(-1)) and pyrolysis aqueous phase (3.2-18.5 µg kg(-1)). After the determination of lead in the samples, it was possible to estimate the relative distribution of this element in the fractions of the pyrolysis products, and it was observed that most of the lead present in the biomass was eliminated to the environment during the pyrolysis process, with a significant portion retained in the ashes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2015.08.041DOI Listing

Publication Analysis

Top Keywords

µg kg-1
24
determination lead
12
lead biomass
12
pyrolysis process
8
direct solid
8
solid liquid
8
liquid sample
8
sample analysis
8
hr-cs aas
8
pyrolysis aqueous
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!