Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Patients with pulmonary regurgitation after tetralogy of Fallot repair have impaired aerobic capacity; one of the reasons is the decreasing global ventricular performance at exercise, reflected by decreasing peak oxygen pulse. The aims of our study were to evaluate the impact of pulmonary valve replacement on peak oxygen pulse in a population with pure pulmonary regurgitation and with different degrees of right ventricular dilatation and to determine the predictors of peak oxygen pulse after pulmonary valve replacement. The mean and median age at pulmonary valve replacement was 27 years. Mean pre-procedural right ventricular end-diastolic volume was 182 ml/m2. Out of 24 patients, 15 had abnormal peak oxygen pulse before pulmonary valve replacement. We did not observe a significant increase in peak oxygen pulse after pulmonary valve replacement (p=0.76). Among cardiopulmonary test/MRI/historical pre-procedural parameters, peak oxygen pulse appeared to be the best predictor of peak oxygen pulse after pulmonary valve replacement (positive and negative predictive values, respectively, 0.94 and 1). After pulmonary valve replacement, peak oxygen pulse was well correlated with left ventricular stroke and end-diastolic volumes (r=0.67 and 0.68, respectively). Our study confirms the absence of an effect of pulmonary valve replacement on peak oxygen pulse whatever the initial right ventricular volume, reflecting possible irreversible right and/or left ventricle lesions. Pre-procedural peak oxygen pulse seemed to well predict post-procedural peak oxygen pulse. These results encourage discussions on pulmonary valve replacement in patients showing any decrease in peak oxygen pulse during their follow-up.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1017/S1047951115002504 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!