A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of radiation-induced peripheral nerve injury in rabbits with MR neurography using diffusion tensor imaging and T2 measurements: Correlation with histological and functional changes. | LitMetric

Purpose: To investigate the potential of diffusion tensor imaging (DTI) and T2 measurements in the evaluation of radiation-induced peripheral nerve injury (RIPNI).

Materials And Methods: RIPNI was produced in a randomly selected side of sciatic nerve in each of 21 rabbits while the contralateral side served as the control. The limb function and MR parameters were evaluated over a 4-month period. Fractional anisotropy (FA), axial diffusivity (λ∥ ), radial diffusivity (λ⊥ ) and T2 values were obtained using 3T MR for quantitative analysis. Two animals were randomly killed for histological evaluation at each timepoint.

Results: The T2 value of irradiated nerve increased at 1 day (63.95 ± 15.60, P = 0.012) and was restored at 1 month (52.34 ± 5.38, P = 0.105). It increased progressively at 2 to 4 months (60.39 ± 10.60, 66.96 ± 6.08, 75.51 ± 7.39, all P < 0.01). λ⊥ significantly increased at 1 day (0.82 ± 0.44, P = 0.046) and slightly decreased at 1 month (0.61 ± 0.17, P < 0.001). It increased gradually from 2 to 3 months (0.84 ± 0.29, 1.13 ± 0.33, both P < 0.001) followed by a decline at 4 months (0.83 ± 0.17, P < 0.001). FA was statistically lower than the contralateral sides at 1 to 4 months (0.72 ± 0.08, 0.60 ± 0.12, 0.51 ± 0.11, 0.62 ± 0.06, all P < 0.01). Changes in FA and λ⊥ correlated well with the functional and pathological changes in irradiated nerve.

Conclusion: DTI may be a more sensitive and accurate method to evaluate RIPNI compared with T2 measurements. FA and λ⊥ are promising quantitative indices in monitoring RIPNI. J. Magn. Reson. Imaging 2016;43:1492-1499.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.25114DOI Listing

Publication Analysis

Top Keywords

evaluation radiation-induced
8
radiation-induced peripheral
8
peripheral nerve
8
nerve injury
8
diffusion tensor
8
tensor imaging
8
increased day
8
017 0001
8
nerve
4
injury rabbits
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!