In recent years, aortic aneurysm treatment with stent graft grafting in the X-ray fluoroscopy is increasing. This is an endovascular therapy, because it is a treatment which includes the risk of radiation damage, having to deal with radiation damage, to know in advance is important. In this study, in order to grasp the trend of exposure stent graft implantation in a hybrid operating room (OR) system, focusing on clinical data (entrance skin dose and fluoroscopy time), was to count the total. In TEVAR and EVAR, fluoroscopy time became 13.40 ± 7.27 minutes, 23.67 ± 11.76 minutes, ESD became 0.87 ± 0.41 mGy, 1.11 ± 0.57 mGy. (fluoroscopy time of EVAR was 2.0 times than TEVAR. DAP of EVAR was 1.2 times than TEVAR.) When using the device, adapted lesions and usage are different. This means that care changes in exposure-related factors. In this study, exposure trends of the stent graft implantation was able to grasp. It can be a helpful way to reduce/optimize the radiation dose in a hybrid OR system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.6009/jjrt.2015_JSRT_71.12.1215 | DOI Listing |
Ann Thorac Surg Short Rep
September 2023
Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, Calgary, Alberta, Canada.
Hybrid arch repair (HAR) combines surgical reconstruction of the ascending aorta and arch debranching with stent graft deployment into the descending thoracic aorta in an effort to reduce the morbidity associated with conventional open total arch replacement. We describe a case of delayed presentation for 2 thoracic aortic wall injuries caused by stent graft migration after type II HAR. This report highlights an important late complication of HAR and the need for careful device selection.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
September 2023
Department of Thoracic Surgery, Osaka General Medical Center, Osaka, Japan.
A 60-year-old man with no history of recurrent pneumonia was diagnosed by screening enhanced computed tomography of the chest with pulmonary sequestration in the right lower lobe with 2 aberrant systemic arteries, 1 of which was markedly aneurysmal and thrombosed immediately after its bifurcation from the descending aorta. During hybrid operation consisting of thoracic endovascular stent graft implantation and right lower lobectomy, the aberrant arteries were ligated by an endoscopic stapler. The patient had no postoperative complications and was discharged on postoperative day 6.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Division of Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, Florida.
Coronary vasospasm involves constriction of the coronary arteries and has been described after manipulation of the coronary arteries (ie, after stenting or bypass grafting). This report details the case of a 57-year-old man who presented with an endoleak after thoracic endovascular aortic repair. He underwent a frozen elephant trunk procedure and postoperatively had diffuse coronary vasospasm, demonstrated on pre- and post-vasospasm cardiac catheterization.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.
Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Department of Cardiovascular Surgery, Teine Keijinkai Hospital, Sapporo, Japan.
We report on a successful thoracic endovascular aortic repair for perigraft seroma (PGS) after ascending aorta replacement (AAR). An 82-year-old man underwent AAR. Two years after the operation, computed tomography showed a 75-mm PGS around the ascending aorta.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!