From the *Department of Radiology, Hallym University College of Medicine, Hallym University Sacred Heart Hospital, Anyang, Gyeonggi; †Department of Radiology, ‡Research Institute of Radiology, §Department of Pulmonary and Critical Care Medicine, and ║Clinical Research Center for Chronic Obstructive Airway Diseases, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.

Published: May 2016

Objectives: The aim of this study was to assess the feasibility of combined xenon-enhanced ventilation (V) and iodine-enhanced perfusion (Q) dual-energy computed tomography (DECT) to evaluate regional V and Q status in patients with chronic obstructive pulmonary disease (COPD).

Materials And Methods: Combined V and Q DECT imaging was performed in 52 prospectively enrolled male COPD patients. Virtual noncontrast images, V maps, and Q maps were anatomically coregistered with deformable registration and evaluated using in-house software. After normalization of the V and Q values of each pixel, normalized V and Q, V/Qratio, and VQmin (ie, the smaller of the V and Q in each pixel) maps were generated. For visual analysis, the V/Qratio pattern was determined to be matched, mismatched, or reversed mismatched and compared with the regional disease patterns--emphysema with/without bronchial wall thickening, bronchial wall thickening, or normal parenchyma--in each segment. The mean V, Q, V/Qratio, and VQmin values and the standard deviation of the V/Qratio (V/QSD) of each patient were quantified and compared with pulmonary function test (PFT) parameters using the Pearson correlation test.

Results: Segments with normal parenchyma showed a matched V/Qratio pattern, whereas segments with bronchial wall thickening commonly showed a reversed mismatched V/Qratio pattern. In the emphysema areas, the matched, mismatched, and reversed mismatched patterns were mixed without a dominant pattern. In quantitative analysis, the mean V, Q, VQmin, and V/Qratio values were significantly and positively correlated with PFT parameters (r = 0.290-0.819; P < 0.05). The V/QSD was significantly and negatively correlated with PFT parameters (r = -0.439 to -0.736; P < 0.001). VQmin values showed the best correlation with PFT parameters (r = 0.483-0.819; P < 0.001).

Conclusions: Visual and quantitative assessment of the regional V, Q, V/Qratio, and VQmin is feasible with combined V and Q DECT imaging and significantly correlate with PFT results in COPD patients. Assessing disease patterns using conventional computed tomography images may not provide correct evaluation of regional V and Q in COPD patients with emphysema.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLI.0000000000000239DOI Listing

Publication Analysis

Top Keywords

pft parameters
16
computed tomography
12
copd patients
12
v/qratio vqmin
12
v/qratio pattern
12
reversed mismatched
12
bronchial wall
12
wall thickening
12
assessment regional
8
dual-energy computed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!