Impact of Age on Stent Strut Coverage and Neointimal Remodeling as Assessed by Optical Coherence Tomography.

Medicine (Baltimore)

From the Department of Cardiology, 2nd Affiliated Hospital of Harbin Medical University, Harbin, P.R. China (SZ); and the Key Laboratory of Myocardial Ischemia, Chinese Ministry of Education, Harbin, P.R. China (ZH, LF, HD, ZS, SH, JD, MS, LX, JH, BY).

Published: December 2015

While older age associates with adverse percutaneous coronary intervention (PCI) outcomes, detailed information relating age to stent strut coverage and neointimal characteristics is lacking. One hundred nineteen patients with 123 sirolimus-eluting stents (SESs) were divided into 3 groups: group A (≤55 years), group B (56-65 years), and group C (>65 years). At 6 and 12 months of follow-up, optical coherence tomography was performed to assess strut coverage and neointimal remodeling. At 6 months, the proportion of uncovered struts increased with age: 6.1% in group A versus 7.3% in group B versus 11.7% in group C (P < 0.001) while the proportion of embedded struts decreased: 72.1% versus 57.0% vs. 55.0%, respectively (P < 0.001). Mean neointimal thicknesses were 90  μm versus 60  μm versus 60  μm, respectively (P < 0.001), and neointimal areas were 0.82  mm2 versus 0.52  mm2 versus 0.57  mm2 (P < 0.001). At 12 months, the proportion of uncovered struts increased with age (3.9% vs. 3.3% vs. 4.9 %; P < 0.001), while mean neointimal thicknesses were 100 versus 70 versus 80  μm (P < 0.001) and neointimal areas were 0.87 versus 0.60 versus 0.67  mm2 (P < 0.001). Patients ≤55 years receiving SES showed highest strut coverage and neointimal repair rate compared with the other 2 groups. A "catch-up phenomenon" appeared to occur in the oldest patients, as in the first 6 months the neointima showed lowest endothelial cell coverage and lowest neointimal proliferation rate, whereas from 6 to 12 months, the highest neointimal proliferation rate was seen in the oldest patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5058912PMC
http://dx.doi.org/10.1097/MD.0000000000002246DOI Listing

Publication Analysis

Top Keywords

strut coverage
12
coverage neointimal
12
age stent
8
stent strut
8
neointimal remodeling
8
optical coherence
8
coherence tomography
8
years group
8
group versus
8
group
6

Similar Publications

Background: Elective unprotected left main (ULM) percutaneous coronary intervention (PCI) has long-term mortality rates comparable to surgical revascularization, thanks to advances in drug-eluting stent (DES) design, improved PCI techniques, and frequent use of intravascular imaging. However, urgent PCI of ULM culprit lesions remains associated with high in-hospital mortality and unfavourable long-term outcomes, including DES restenosis and stent thrombosis (ST). This analysis aimed to examine the long-term outcomes and healing of DES implanted in ULM during primary PCI using high-resolution optical coherence tomography (OCT) imaging.

View Article and Find Full Text PDF

The COMBO stent is a unique stent on which the CD34 antibody is mounted to capture CD34 + endothelial progenitor cells (EPCs) and from which sirolimus is eluted to suppress neointimal hyperplasia. The COMBO stent aims to induce early re-endothelialization and vascular healing and to prevent restenosis. In the clinical setting, however, the effects of the COMBO stent have not been validated in terms of EPC biology.

View Article and Find Full Text PDF
Article Synopsis
  • Early vascular healing after drug-eluting stent implantation is crucial for positive patient outcomes and reducing in-stent thrombosis.
  • A study compared outcomes for patients with non-ST elevation acute coronary syndrome undergoing PCI, using either optical coherence tomography (OCT) or traditional angiography guidance.
  • Results showed that at 3 months, OCT guidance led to better strut coverage than angiography, but the advantage decreased by 6 months, suggesting healing may depend more on time than the guidance method used.*
View Article and Find Full Text PDF

Purpose: To compare the endothelial coverage of different stents in porcine carotid arteries. Research problem: How effective are polyurethane stents (PU) and PU + rapamycin (PU + RAPA) compared to bare-metal stents on endothelial coverage by neointima in pigs after 28 days?

Methods: The methodology had two phases for an interventional, experimental, prospective study, with three Moura pigs, 12 weeks old and weighing between 19 and 22.5 kg.

View Article and Find Full Text PDF
Article Synopsis
  • * Twenty patients were enrolled, and results after 8 months showed minimal in-stent late lumen loss (0.7 mm) and complete stent strut coverage, indicating successful healing.
  • * There were no adverse cardiovascular events reported within the same period, suggesting that the new stent design is safe and effective in treating coronary artery disease.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?