Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Optical coherence tomography angiography (OCT-A) is a new diagnostic non-invasive method by which the vascular structures of the retina and choroid can be visualized three-dimensionally without need for using fluorescence dyes. The technology of OCT-A is an advancement of the OCT. By means of more powerful software and hardware used for OCT-A not only morphological but also retinal and choroidal vascular perfusion analyses can be performed. In this article, the principles and applications of OCT-A are discussed and compared to other non-invasive diagnostic devices for visualization of the retinal and choroidal blood circulation.
Methods: This article is based on a selective literature review and analyses of own data.
Results: The advantages of OCT-A include easy application without the need for mydriasis or intravenous injection of fluorescence dyes and also the exact three-dimensional localization of vascular changes. In the case of retinal pathologies there is a considerable difference between software-assisted automatic segmentation and the real architecture of the retina, which must be taken into consideration in the clinical interpretation.
Conclusion: Of all noninvasive devices for visualization of the retinal and choroidal circulation, OCT-A is the only one which can already be implemented into the clinical routine. With this novel imaging device retinal and choroidal alterations can be visualized in a depth- selective manner and without masking affects, such as pooling or staining phenomena.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00347-015-0184-6 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!