Background: The aim of the study was to evaluate the effects of micro-electric current on sodium hypochlorite's (NaOCl's) tissue-dissolution abilities, compared with other activation methods, including sonic, ultrasonic, pipetting, and temperature.
Methods: Bovine muscle tissues (n = 154) with standard sizes and weights were prepared and divided into two temperature groups: room temperature and 45 °C. Each temperature group was divided into seven sub-groups by activation methods: D = distilled water (-control); NaOCl = 5.25 % passive NaOCl (+ control); P = 5.25 % NaOCl with pipetting; SA = 5.25 % NaOCl with sonic activation; UA = 5.25 % NaOCl with ultrasonic activation; E-NaOCl = 5.25 % NaOCl with micro-electric current; and E-NaOCl + P = 5.25 % NaOCl with micro-electric current and pipetting. Specimens were weighed before and after treatment. Average, standard deviation, minimum, maximum, and median were calculated for each group. Resulting data were analyzed statistically using multi-way ANOVA and Tukey HSD tests. The level of the alpha-type error was set at < 0.05.
Results: At room temperature, the E-NaOCl + P group dissolved the highest amount of tissue (p < 0.05), and the UA, SA, and P groups dissolved significantly higher amounts of tissue than did the positive control or E-NaOCl groups (p < 0.05). At 45 °C, there was no significant difference between the SA and E-NaOCl groups (p > 0.05), and the E-NaOCl + P group dissolved a higher amount of tissue than any other group (p < 0.05).
Conclusions: Using NaOCl with micro-electric current can improve the tissue-dissolving ability of the solution. In addition, this method can be combined with additional techniques, such as heating and/or pipetting, to achieve a synergistic effect of NaOCl on tissue dissolution.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4683763 | PMC |
http://dx.doi.org/10.1186/s12903-015-0152-1 | DOI Listing |
Angew Chem Int Ed Engl
November 2024
Fujian Key Laboratory of Polymer Materials, College of Chemistry and Materials Science, Fujian Normal University, Fuzhou, China.
Achieving efficient xenon/krypton (Xe/Kr) separation in emerging hydrogen-bonded organic frameworks (HOFs) is highly challenging because of the lack of gas-binding sites on their pore surfaces. Herein, we report the first microporous HOF (HOF-FJU-168) based on hydrogen-bonded helical chains, which prevent self-aggregation of the pyrene core, thereby preserving open pyrene sites on the pore surfaces. Its activated form, HOF-FJU-168a is capable of separating Xe/Kr under ambient conditions while achieving an excellent balance between adsorption capacity and selectivity.
View Article and Find Full Text PDFChemosphere
November 2023
School of Environment and Energy, South China University of Technology, Guangzhou, 510006, China; The Key Laboratory of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, Guangzhou, 510006, China; The Key Laboratory of Environmental Protection and Eco-Remediation of Guangdong Regular Higher Education Institutions, Guangzhou, 510006, China; Guangdong Provincial Key Laboratory of Solid Wastes Pollution Control and Recycling, Guangzhou, 510006, China. Electronic address:
Zero-valent iron (Fe) is restricted in phosphate removal due to the formation of a passive P-Fe layer on its surface. A micro-electric field (0.20 mA cm) was employed in Fe column to facilitate iron corrosion for enhanced phosphate removal with a Fe column as the control.
View Article and Find Full Text PDFBioresour Technol
April 2023
College of Energy and Environment, Southeast University, Nanjing, Jiangsu 210096, PR China. Electronic address:
To remove membrane fouling, a bio-electrochemical system that can generate a micro-electric field and micro-current was constructed. After 11 days of operation, the trans-membrane pressure difference of membrane modules in the open- and closed-circuit groups increased by 35.8 kPa and 6.
View Article and Find Full Text PDFMicromachines (Basel)
March 2022
Center of Micro/Nano Manufacturing Technology (MNMT-Dublin), School of Mechanical & Materials Engineering, University College Dublin, Belfield, D04 V1W8 Dublin, Ireland.
Electropolishing (EP) is most widely used as a metal finishing process. It is a non-contact electrochemical process that can clean, passivate, deburr, brighten, and improve the biocompatibility of surfaces. However, there is clear potential for it to be used to shape and form the topology of micro-scale surface features, such as those found on the micro-applications of additively manufactured (AM) parts, transmission electron microscopy (TEM) samples, micro-electromechanical systems (MEMs), biomedical stents, and artificial implants.
View Article and Find Full Text PDFBioresour Technol
March 2017
China Institute of Water Resource and Hydropower Research, Beijing 100038, China.
The constructed wetland coupled with biofilm-electrode reactor (CW-BER) is a novel technology to treat wastewater with a relatively high level of total inorganic nitrogen (TIN) concentration. The main objective of this study is to investigate the effects of C/Ns, TIN concentrations, current intensities, and pH on the removal of nitrogen in CW-BER; a control system (CW) was also constructed and operated with similar influent conditions. Results indicated that the current, inorganic carbon source and hydrogen generated by the micro-electric field could significantly improve the inorganic nitrogen removal with in CW-BER, and the enhancement of average removal rate on NH-N, NO-N, and TIN was approximately maintained at 5-28%, 5-26%, and 3-24%, respectively.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!