A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel and easy FxCycle™ violet based flow cytometric method for simultaneous assessment of DNA ploidy and six-color immunophenotyping. | LitMetric

Abnormal DNA ploidy is a valuable prognostic factor in many neoplasms, especially in hematological neoplasms like B-cell acute lymphoblastic leukemia (B-ALL) and multiple myeloma (MM). Current methods of flow-cytometric (FC) DNA-ploidy evaluation are either technically difficult or limited to three- to four-color immunophenotyping and hence, challenging to evaluate DNA-ploidy in minute tumor population with background rich of its normal counterpart cells and other hematopoietic cells. We standardized a novel sensitive and easy method of simultaneous evaluation of six- to seven-color immunophenotyping and DNA-ploidy using a dye-FxCycle Violet (FCV). Linearity, resolution, and coefficient of variation (CV) for FCV were studied using chicken erythrocyte nuclei. Ploidy results of FCV were compared with Propidium iodide (PI) in 20 samples and intra-assay variation for FCV was studied. Using this six-color immunophenotyping & FCV-protocol DNA-ploidy was determined in bone-marrow samples from 124 B-ALL & 50 MM patients. Dilution experiment was also conducted to determine the sensitivity in detection of aneuploidy in minute tumor population. FCV revealed high linearity and resolution in 450/50 channel. On comparison with PI, CV of Go/G1-peak with FCV (mean-CV 4.1%) was slightly higher than PI (mean-CV 2.9%) but had complete agreement in ploidy results. Dilution experiment showed that aneuploidy could be accurately detected up to the limit of 0.01% tumor cells. Intra-assay variation was very low with CV of 0.005%. In B-ALL, hypodiploidy was noted in 4%, hyperdiploidy in 24%, near-hyperdiploidy in 13% and remaining 59% were diploid. In MM, hypodiploidy was in 2%, hyperdiploidy in 58%, near-hyperdiploidy in 8% and remaining 30% were diploid. FCV-based DNA-ploidy method is a sensitive and easy method for simultaneous evaluation of six-color immunophenotyping and DNA analysis. It is useful in DNA-ploidy evaluation of minute tumor population in cases like minimal residual disease and MM precursor conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1002/cyto.a.22803DOI Listing

Publication Analysis

Top Keywords

method simultaneous
12
six-color immunophenotyping
12
minute tumor
12
tumor population
12
dna ploidy
8
dna-ploidy evaluation
8
sensitive easy
8
easy method
8
simultaneous evaluation
8
linearity resolution
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!