Early Detection and Quantification of Cerebral Venous Thrombosis by Magnetic Resonance Black-Blood Thrombus Imaging.

Stroke

From the Departments of Radiology (Q.Y., X.D., K.L.), Emergency (J.D.), and Neurosurgery (X.J.), Xuanwu Hospital, Capital Medical University, Beijing, China; Biomedical Imaging Research Institute, Cedars Sinai Medical Center, Los Angeles, CA (Q.Y., Z.F., X.Q., Y.X., C.N., D.L.); and MR Research and Development, Siemens Healthcare, Los Angeles, CA (X.B.).

Published: February 2016

Background And Purpose: Early diagnosis of cerebral venous thrombosis (CVT) is currently a major clinical challenge. We proposed a novel magnetic resonance black-blood thrombus imaging technique (MRBTI) for detection and quantification of CVT.

Methods: MRBTI was performed on 23 patients with proven CVT and 24 patients with negative CVT confirmed by conventional imaging techniques. Patients were divided into 2 groups based on the duration of clinical onset: ≤7 days (group 1) and between 7 and 30 days (group 2). Signal/noise ratio was calculated for the detected thrombus, and contrast/noise ratio was measured between thrombus and lumen and also between thrombus and brain tissue. The feasibility of using MRBTI for thrombus volume measurement was explored, and total thrombus volume was calculated for each patient.

Results: In 23 patients with proven CVT, MRBTI correctly identified 113 of 116 segments with a sensitivity of 97.4%. Thrombus signal/noise ratio was 153±57 and 261±95 for group 1 (n=10) and group 2 (n=13), respectively (P<0.01). Thrombus to lumen contrast/noise ratio was 149±57 and 256±94 for group 1 and group 2, respectively. Thrombus to brain tissue contrast/noise ratio was 41±36 and 120±63 (P<0.01), respectively. Quantification of thrombus volume was successfully conducted in all patients with CVT, and mean volume of thrombus was 10.5±6.9 mL.

Conclusions: The current findings support that with effectively suppressed blood signal, MRBTI allows selective visualization of thrombus as opposed to indirect detection of venous flow perturbation and can be used as a promising first-line diagnostic imaging tool.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4729606PMC
http://dx.doi.org/10.1161/STROKEAHA.115.011369DOI Listing

Publication Analysis

Top Keywords

detection quantification
8
cerebral venous
8
venous thrombosis
8
magnetic resonance
8
resonance black-blood
8
thrombus
8
black-blood thrombus
8
thrombus imaging
8
patients proven
8
proven cvt
8

Similar Publications

Background: Faecal egg counts (FECs) are essential for diagnosing helminth infections and guiding treatment decisions. For camels, no evaluations of coproscopic methods regarding precision, sensitivity and correlation between individual and pooled faecal samples are currently available.

Methods: Here, 410 camel faecal samples were collected in 2022 from South Darfur State, Sudan, and analysed to compare the semi-quantitative flotation, McMaster and Mini-FLOTAC methods in terms of precision, sensitivity, inter-rater reliability and helminth egg count correlations, as well as the effects of pooling samples.

View Article and Find Full Text PDF

Biarsenical-based fluorescent labeling of metallothioneins as a method for ultrasensitive quantification of poly-Cys targets.

Anal Chim Acta

February 2025

Department of Chemical Biology, Faculty of Biotechnology, University of Wroclaw, Joliot-Curie 14a, 50-383, Wrocław, Poland. Electronic address:

Background: Mammalian metallothioneins (MTs) play a crucial role in maintaining Zn(II) and Cu(I) homeostasis, as well as regulating the cellular redox potential. They are involved in cancer resistance to cisplatin-related drugs and the sequestration of toxic metal ions. To investigate their participation in specific physiological and pathological processes, it is imperative to develop an analytical method for measuring changes in protein concentration both in vitro and in vivo.

View Article and Find Full Text PDF

Background: The buildup of methylparaben (MP), a broad-spectrum antimicrobial preservative with endocrine-disrupting properties, in environmental sources, especially aquatic systems, has become a significant concern due to its adverse health effects, including allergic reactions, promoting the risk of developing cancer, and inducing reproductive disorders. Hence, introducing inexpensive and easy-to-use monitoring devices for rapid, selective, and sensitive detection and quantification of MP is highly desirable. In this context, electrochemical platforms have proven to be attractive options due to their remarkable features, such as ease of fabrication and use, short response time, and acceptable sensitivity, accuracy, and selectivity.

View Article and Find Full Text PDF

Carbon dot embedded hybrid microgel from synthesis to sensing: Experimental and theoretical approach.

Anal Chim Acta

February 2025

Department of Chemistry and Centre of Advanced Studies in Chemistry, Panjab University, Chandigarh, 160014, India; Department of Applied Chemistry, Maulana Abul Kalam Azad University of Technology, Simhat, Haringhata, West Bengal, 741249, India. Electronic address:

Background: The intellectual progress in fabricating artificial probes for selective appraisal of biologically admissible amino acids has displayed exponential growth in recent era.The neoteric era in material science has witnessed the significant application of carbon quantum dots (CQDs). However, the hybrid microgel of CQDs was less explored.

View Article and Find Full Text PDF

Background: Edible oils are susceptible to contamination with polycyclic aromatic hydrocarbons (PAHs) throughout production, storage, and transportation processes due to their lipophilic nature. The necessity of quantifying PAHs present in complex oil matrices at trace levels, which bind strongly to impurities in oil matrices, poses a major challenge to the accurate quantification of these contaminants. Therefore, the development of straightforward and effective methods for the separation and enrichment of PAHs in oil samples prior to instrumental analysis is paramount to guaranteeing food safety.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!