A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Study on the Effects of Different Ferron System, Ferron Solubility, Experimental Temperature and Other Factors for the Accurate Determination of Mononuclear Aluminum Concentration in Aqueous Solution]. | LitMetric

Ferron colorimetric method has been widely used in aluminum speciation analysis. However, some important factors that may affect the accurate determination of mononuclear Al concentration have not been studied yet. Using molar absorption coefficient ε as a key indicator, the critical issues in Al-Ferron coloring reaction system have been investigated experimentally in this paper, including different Ferron system, Ferron solubility, experimental temperature, ionic strength and the reference system. The results show that three vital factors (different Ferron colorimetric system, Ferron solubility and experimental temperature) would significantly affect the accurate measurement of mononuclear Al concentration; whereas, other two factors like ionic strength and the reference have litter influence. Base on our experimental results and statistic analysis of relevant important literatures, we suggest that optimizing colorimetric conditions and standardizing operational procedures should be paid much more attention in Ferron colorimetric assay in order to obtain the accurate measurement results.

Download full-text PDF

Source

Publication Analysis

Top Keywords

system ferron
12
ferron solubility
12
solubility experimental
12
experimental temperature
12
ferron colorimetric
12
ferron
8
ferron system
8
accurate determination
8
determination mononuclear
8
affect accurate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!