Effect of posture on (13)C-urea breath test in partial gastrectomy patients.

World J Gastroenterol

Shu-Ming Yin, Fan Zhang, Dong-Mei Shi, Ping Xiang, Li Xiao, Yi-Qin Huang, Gan-Sheng Zhang, Zhi-Jun Bao, Division of Gastroenterology, Huadong Hospital, Shanghai Medical College of Fudan University, Shanghai 200040, China.

Published: December 2015

Aim: To investigate whether posture affects the accuracy of (13)C-urea breath test ((13)C-UBT) for Helicobacter pylori (H. pylori) detection in partial gastrectomy patients.

Methods: We studied 156 consecutive residual stomach patients, including 76 with H. pylori infection (infection group) and 80 without H. pylori infection (control group). H. pylori infection was confirmed if both the rapid urease test and histology were positive during gastroscopy. The two groups were divided into four subgroups according to patients' posture during the (13)C-UBT: subgroup A, sitting position; subgroup B, supine position; subgroup C, right lateral recumbent position; and subgroup D, left lateral recumbent position. Each subject underwent the following modified (13)C-UBT: 75 mg of (13)C-urea (powder) in 100 mL of citric acid solution was administered, and a mouth wash was performed immediately; breath samples were then collected at baseline and at 5-min intervals up to 30 min while the position was maintained. Seven breath samples were collected for each subject. The cutoff value was 2.0‰.

Results: The mean delta over baseline (DOB) values in the subgroups of the infection group were similar at 5 min (P > 0.05) and significantly higher than those in the corresponding control subgroups at all time points (P < 0.01). In the infection group, the mean DOB values in subgroup A were higher than those in other subgroups within 10 min and peaked at the 10-min point (12.4‰ ± 2.4‰). The values in subgroups B and C both reached their peaks at 15 min (B, 13.9‰ ± 1.5‰; C, 12.2‰ ± 1.7‰) and then decreased gradually until the 30-min point. In subgroup D, the value peaked at 20 min (14.7‰ ± 1.7‰). Significant differences were found between the values in subgroups D and B at both 25 min (t = 2.093, P = 0.043) and 30 min (t = 2.141, P = 0.039). At 30 min, the value in subgroup D was also significantly different from those in subgroups A and C (D vs C: t = 6.325, P = 0.000; D vs A: t = 5.912, P = 0.000). The mean DOB values of subjects with Billroth I anastomosis were higher than those of subjects with Billroth II anastomosis irrespectively of the detection time and posture (P > 0.05).

Conclusion: Utilization of the left lateral recumbent position during the procedure and when collecting the last breath sample may improve the diagnostic accuracy of the (13)C-UBT in partial gastrectomy patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4671045PMC
http://dx.doi.org/10.3748/wjg.v21.i45.12888DOI Listing

Publication Analysis

Top Keywords

partial gastrectomy
12
pylori infection
12
infection group
12
position subgroup
12
lateral recumbent
12
recumbent position
12
dob values
12
values subgroups
12
13c-urea breath
8
breath test
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!