Post-stenotic plug-like jet with a vortex ring demonstrated by 4D flow MRI.

Magn Reson Imaging

Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea; Department of Convergence Medicine, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea. Electronic address:

Published: May 2016

Purpose: To investigate the details of the flow structure of a plug-like jet that had a vortex ring in pulsatile stenotic phantoms using 4D flow MRI.

Method: Pulsatile Newtonian flows in two stenotic phantoms with 50% and 75% reductions in area were scanned by 4D flow MRI. Blood analog working fluid was circulated via the stenotic phantom using a pulsatile pump at a constant pulsating frequency of 1Hz. The velocity and vorticity fields of the plug-like jet with a vortex ring were quantitatively analyzed in the spatial and temporal domains.

Results: Pulsatile stenotic flow showed a plug-like jet at the specific stenotic degree of 50% in our pulsatile waveform design. This plug-like jet was found at the decelerating period in the post-stenotic region of 26.4mm (1.2 D). It revealed a vortex ring structure with vorticity strength in the range of ±100s(-1).

Conclusion: We observed a plug-like jet with a vortex ring in pulsatile stenotic flow by in vitro visualization using 4D flow MRI. In this plug-like jet, the local fastest flow region occurred at the post-systole phase in the post-stenotic region, which was distinguishable from a typical stenotic jet flow at systole phase.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2015.11.010DOI Listing

Publication Analysis

Top Keywords

plug-like jet
28
vortex ring
20
jet vortex
16
flow mri
12
pulsatile stenotic
12
flow
9
jet
8
ring pulsatile
8
stenotic phantoms
8
stenotic flow
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!