With the pressing demand of environmentally friendly personal transportation vehicles, mobility scooters become more and more popular for the short-distance transportation. Similar to pedestrians and bicyclists, scooter riders are vulnerable road users and are expected to receive severe injuries during traffic accidents. In this research, a MADYMO model of vehicle-scooter crash scenarios is numerically set up. The model of the vehicle with the scenario is validated in pedestrian-vehicle accident investigation with previous literatures in terms of throwing distance and HIC15 value. HIC15 values gained at systematic parametric studies. Injury information from various vehicle crashing speeds (i.e. from 10m/s to 24m/s), angles (i.e. from 0 to 360°), scooter's speeds (i.e. from 0m/s to 4m/s), contact positions (i.e. left, middle and right bumper positions) are extracted, analyzed and then compared with those from widely studied pedestrian-vehicle and bicycle-vehicle accidents. Results show that the ESS provides better impact protection for the riders. Riding ESS would not increase the risk higher than walking at the same impact conditions in terms of head injury. The responsible reasons should be the smaller friction coefficient between the wheel-road than the heel-road interactions, different body gestures leading to different contact positions, forces and timing. Results may shed lights upon the future research of mobility scooter safety analysis and also the safety design guidance for the scooters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aap.2015.10.022 | DOI Listing |
Oper Orthop Traumatol
January 2025
Klinik für Unfall‑, Hand und Wiederherstellungschirurgie, Universitätsmedizin Rostock, Schillingallee 35, 18057, Rostock, Deutschland.
Objective: Treatment with transcutaneous osseointegrated prosthesis systems (TOPS) for short femoral amputation stumps aims to restore independent walking ability after proximal femoral amputation by direct bone-guided prosthesis anchorage. This cannot be safely achieved with conventional socket prostheses due to the mechanically inadequate socket contact surface.
Indications: Treatment of patients with short transfemoral stumps who cannot be mobilized sufficiently with conventional socket prostheses.
Biomed Phys Eng Express
January 2025
Children's Hospital of Eastern Switzerland, Claudiusstrasse 6, St.Gallen, 9006, SWITZERLAND.
Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.
View Article and Find Full Text PDFJ Exp Orthop
January 2025
Department of Orthopaedic Surgery, Faculty of Medicine The University of Tokyo Tokyo Japan.
Purpose: To clarify the influence of biomechanics on post-operative clinical outcomes in bicruciate-retaining total knee arthroplasty (BCR-TKA).
Methods: Severe medial osteoarthritis who underwent BCR-TKA were examined. Each patient was asked to perform a squat (weight-bearing [WB]) and active assisted knee flexion (non-WB [NWB]) under single fluoroscopy surveillance.
J Int Soc Prev Community Dent
December 2024
Department of Gnathology, San Paolo Dental Building, University of Milan, Milan, Italy.
Aims: To verify the possible association between the stomatognathic and the visual system by analyzing the effects that different mandibular postures may have on the accommodative capacity and ocular convergence and by assessing whether temporomandibular disorders (TMD) can influence visual abilities.
Materials And Methods: A case-control study was performed during a 1-year period on a sample of 100 subjects (50 cases and 50 controls). The subjects underwent a gnathological examination, and two visual tests were performed in three different jaw positions: maximum intercuspation, resting position, and open mouth.
Clin Optom (Auckl)
January 2025
Research Department, Southern College of Optometry, Memphis, TN, USA.
Purpose: To determine the performance of TOTAL30 for Astigmatism (T30fA; Alcon; Fort Worth, TX, USA) contact lenses (CLs) in existing CL wearers who are also frequent digital device users.
Methods: This 1-month, 3-visit study recruited adult, 18- to 40-year-old subjects who were required to use daily digital devices for at least 8 hours per day. All subjects were refit into T30fA CLs.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!