Background: The use of a prosthetic mesh to repair a tissue defect may produce a series of post-operative complications, among which infection is the most feared and one of the most devastating. When occurring, bacterial adherence and biofilm formation on the mesh surface affect the implant's tissue integration and host tissue regeneration, making preventive measures to control prosthetic infection a major goal of prosthetic mesh improvement.

Methods: This article reviews the literature on the infection of prosthetic meshes used in hernia repair to describe the in vitro and in vivo models used to examine bacterial adherence and biofilm formation on the surface of different biomaterials. Also discussed are the prophylactic measures used to control implant infection ranging from meshes soaked in antibiotics to mesh coatings that release antimicrobial agents in a controlled manner.

Results: Prosthetic architecture has a direct effect on bacterial adherence and biofilm formation. Absorbable synthetic materials are more prone to bacterial colonization than non-absorbable materials. The reported behavior of collagen biomeshes, also called xenografts, in a contaminated environment has been contradictory, and their use in this setting needs further clinical investigation. New prophylactic mesh designs include surface modifications with an anti-adhesive substance or pre-treatment with antibacterial agents or metal coatings.

Conclusions: The use of polymer coatings that slowly release non-antibiotic drugs seems to be a good strategy to prevent implant contamination and reduce the onset of resistant bacterial strains. Even though the prophylactic designs described in this review are mainly focused on hernia repair meshes, these strategies can be extrapolated to other implantable devices, regardless of their design, shape or dimension.

Download full-text PDF

Source
http://dx.doi.org/10.1089/sur.2015.078DOI Listing

Publication Analysis

Top Keywords

hernia repair
12
bacterial adherence
12
adherence biofilm
12
biofilm formation
12
prosthetic mesh
8
measures control
8
mesh
6
prosthetic
5
bacterial
5
mesh infection
4

Similar Publications

Background: Transabdominal pre-peritoneal inguinal hernia repair using the da Vinci Single-Port robot (SP-TAPP) is currently performed in few centers. We aimed to define the learning curve for SP-TAPP by analyzing operative times.

Methods: The operative times of 122 SP-TAPP performed between 2019 and 2024 were retrospectively analyzed.

View Article and Find Full Text PDF

Comparative analysis of efficacy and quality of life between totally extraperitoneal sublay and intraperitoneal onlay mesh repair for ventral hernia.

Sci Rep

January 2025

Department of General Surgery, Shaoxing Central Hospital (The Central Affiliated Hospital, Shaoxing University), Shaoxing, 312030, Zhejiang Province, China.

Ventral hernias pose a prevalent challenge in abdominal wall surgery, with ongoing advancements in repair techniques designed to enhance patient outcomes. This study evaluates the efficacy, safety, and socio-economic impact of Totally Extraperitoneal Sublay Repair (TES) versus Laparoscopic Intraperitoneal Onlay Mesh Repair (IPOM) for small to medium-sized ventral hernias, with a particular focus on postoperative quality of life and patient satisfaction. A retrospective cohort study was conducted, encompassing 125 patients who underwent ventral hernia repair between May 2018 and November 2023.

View Article and Find Full Text PDF

Production and Characterization of Oil-Loaded, Semi-Resorbable, Tri-Layered Hernia Mesh.

Polymers (Basel)

January 2025

Institute of Graduate Studies, Bioengineering Division, Tokat Gaziosmanpaşa University, 60250 Tokat, Türkiye.

Hernia repair is the most common surgical operation applied worldwide. Mesh prostheses are used to support weakened or damaged tissue to decrease the risk of hernia recurrence. However, the patches currently used in clinic applications have significant short-term and long-term risks.

View Article and Find Full Text PDF

Incisional ventral hernia repair remains a challenging surgery for abdominal wall surgeons. We report the results at 48 months post-surgery regarding open ventral hernia repair (OVHR), analyzing the recurrence rate and incidence of chronic pain. This was a retrospective, observational study of 111 consecutive patients who underwent OVHR.

View Article and Find Full Text PDF

To optimize the efficacy of analgesia for patients receiving laparoscopic inguinal hernia repair, peri-operative pain neuroscience education (PNE) as a pain-specific cognitive therapy was incorporated into multi-modal analgesia. A randomized controlled trial was conducted to compare conventional analgesia (group CA) and the addition of pain neuroscience education into it (group PNE) in patients receiving laparoscopic inguinal hernia repair. Characteristics of peri-operative pain was evaluated with Douleur Neuropathique 4 questionnaire (DN-4), central sensitization inventory (CSI), pain catastrophizing scale (PCS) post-operatively and pressure pain threshold.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!