A pilot study of a hand-held camera in a busy burn centre: Prediction of patient length of recuperation with wound temperature.

Burns

St Andrews Centre for Burns & Plastic Surgery, Mid Essex NHS Hospitals Trust, Broomfield, Chelmsford, Essex CM1 7ET, United Kingdom; St Andrew's Anglia Ruskin (StAAR) Research Group, United Kingdom.

Published: May 2016

Aim: The aim of our study was to evaluate temperature differences of burns looking at their prognostic ability to predict healing at the 21 day mark.

Materials And Method: Thirty two burns in 26 patients aged 1-71 years old were photographed with a FLIR T650 camera. Environment, reflected, and body core temperature of the patients were measured. Skin emissivity was constant 0.98. Pictures were analyzed with R&D FLIR Software. Minimal and average burn temperatures and skin temperature in 255 pixel squares were measured. Patients were divided into healed and not healed groups. Statistical analysis was performed with SPSS 20 (IBM Armonk, USA) and p<0.05 was significant.

Results: There were 25 healed and 7 non-healed burns at 21 days. Healed burns were significantly warmer than non-healed burns (p<0.05). There was a statistically significant strong, negative correlation between the difference of minimal burns temperatures and healthy skin temperatures with days needed to heal the burns (p=0.001; rho=-0.564).

Conclusion: Infrared camera seems to be useful equipment in predicting burns' healing time. However further clinical studies need to be done.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.burns.2015.10.028DOI Listing

Publication Analysis

Top Keywords

pilot study
4
study hand-held
4
hand-held camera
4
camera busy
4
busy burn
4
burn centre
4
centre prediction
4
prediction patient
4
patient length
4
length recuperation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!