AI Article Synopsis

  • A novel method using TurborFlow online solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for screening and confirming 88 veterinary drugs in milk from various families, achieving results in under 39 minutes.
  • The method includes sample dilution and ultrasonic extraction, followed by automated clean-up and detection using selected reaction monitoring mode (SRM), and has shown high reliability with R(2) values above 0.9930.
  • Validation results show limits of detection as low as 0.2-2.0 μg/kg, and overall recovery rates for spiked compounds range from 63.1% to 117.4%, demonstrating its effectiveness and potential

Article Abstract

A novel method based on TurborFlow online solid phase extraction (SPE) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been established for simultaneous screening and confirmation of 88 wide-range veterinary drugs belonging to eight families (20 sulfonamides, 7 macrolides, 15 quinolones, 8 penicillins, 13 benzimidazoles, 4 tetracyclines, 2 sedatives, and 19 hormones) in milk. The preparation method consists of sample dilution and ultrasonic extraction, followed by an automated turbulent flow cyclone chromatography sample clean-up system. The detection was achieved in selected reaction monitoring mode (SRM). The total run time was within 39 min, including automated extraction, analytical chromatography and re-equilibration of the turboflow system. The optimization of different experimental parameters including extraction, purification, separation, and detection were evaluated separately in this study. The developed method was validated and good performing characteristics were obtained. The linear regression coefficients (R(2)) of matrix-match calibration standard curves established for quantification were higher than 0.9930. The limits of detection (LOD) were in the range of 0.2-2.0 μg/kg given by signal-noise ratio ≥3 (S/N) and the limits of quantification (LOQ, S/N≥10) ranged between 0.5 μg/kg and 10 μg/kg. Average recoveries of spiked target compounds with different levels were between 63.1% and 117.4%, with percentage relative standard deviations (RSD) in the range of 3.3-17.6%. The results indicated that the developed method has great potential for the routine laboratory analysis of large numbers of samples on measuring different classes of compounds. In comparison to traditional procedures, the automated sample clean-up ensures rapid, effective, sensitive analyses of veterinary drugs in milk.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2015.10.037DOI Listing

Publication Analysis

Top Keywords

turborflow online
8
liquid chromatography-tandem
8
chromatography-tandem mass
8
mass spectrometry
8
veterinary drugs
8
sample clean-up
8
developed method
8
rapid determination
4
determination veterinary
4
veterinary drug
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!